Ask Experts Questions for FREE Help !
Ask
    kinsellm's Avatar
    kinsellm Posts: 1, Reputation: 1
    New Member
     
    #1

    Oct 24, 2008, 12:14 PM
    Carrier 58DHC075 furnace ignites but flame goes out
    I have a Carrier natural gas furnace. Model 58DHC075-HC
    I think it is 92000 BTU. It was made aroung 1990
    The furnace ignites OK, but then after a few seconds the flame foes out.
    I guess this might be due to a faulty flame detector. Is there any way I can be sure of thuis befoire I order a fl;ame detorcor?
    Is there any other possible cause I should check?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Oct 24, 2008, 06:31 PM
    Carefully remove and clean metal rod on flame sensor with sand paper. Replace and try to fire it over.

    Also see other problems with this unit.

    https://www.askmehelpdesk.com/heatin...te-158980.html
    Joe Mack's Avatar
    Joe Mack Posts: 1, Reputation: 1
    New Member
     
    #3

    Feb 1, 2010, 05:55 AM
    This happened to me but on a more variable scale. Make sure that the outside exhaust is not blowing towards your intake. The oxygen-poor air was being sucked into the intake, and the flame "smothered" and fluttered-out. Re-aimed the exhaust, and has been perfect since.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Carrier Weather Maker 8000 flame sensor [ 10 Answers ]

Hello, I have a Carrier weather maker 8000 and have received error 34. I would like to find the flame sensor so that I may clean it but don't know what it looks like. I have surfed the site and am unable to find it. Can anybody help with this. Thank you in advance, TripleT

Goodman furnace ignites then shuts down [ 3 Answers ]

When my Goodman furnace (CWP#00299785) turns on, the blower works and the burners ignite, but after a few seconds the burners extinguish. Then the burners ignite again for a few seconds and extinguish once again. Please tell me what part(s) I need and where those parts are located on the furnace....

3A fuse blowing after furnace ignites [ 5 Answers ]

'Working on a 10-yr old Goodman GMP050-3. A/C is okay, but no heat. Circuit board and ignitor were just replaced and the flame sensor has been cleaned. The unit comes on, status light solid, ignitor glows, gas comes on and ignites, but after 2-3 seconds the 3A fuse on the board blows.

New thermostat, Furnace ignites fire but no heat [ 3 Answers ]

Hi My furnace and thermostat was working fine until two weeks ago. So I replaced the thermostat and the heat started working for the first day then it stopped. I tried to turn up the degrees on the thermostat and I checked the furnace. The electric ignitor was working fine and there was fire...


View more questions Search