PDA

View Full Version : Trane xe 1000 blower motor getting loud and vibrating 2 days later stopped working


bruce97382
Jun 16, 2012, 09:18 PM
Trane XE 1000 blower motor making noise for past 2 days. Getting louder and vibrating. Stopped working only hums and freon line frost. Bad blower?

hvac1000
Jun 16, 2012, 11:03 PM
Trane XE 1000 blower motor making noise for past 2 days. Getting louder and vibrating. Stopped working only hums and freon line frost. Bad blower?

Very well could be a bad blower motor. If you replace the motor make sure you also replace the motor run capacitor that matches the motor you are using as a replacement. NOTE: You also said vibration so check the blower wheel for out of balance conditions. If blower wheel is also out of balance just replace the wheel with like same since they are very hard to balance unless you have the proper tools.