    Remove toilet and convert to shower drain
    Hi! I can work my way around a construction site, but when it comes to plumbing (or HVAC) I have to ask the experts. I'm helping a friend convert a bathroom to a shower room. We intend to remove the sink and toilet, etc, re-tile and have the entire room be a shower. Of course this is an older building with a case iron toilet drain. In my past experience, toilet drains don't have P-traps and therefore if we just convert it to a shower drain without a p-trap we'll get that lovely sewer gas smell constantly. Is there a simple way to convert the toilet drain to something with a p-trap without having to bust up and remove the concrete? Is there some type of adapter on the market for this?

    Thanks in advance!
    Ben
    casairl's Avatar
    casairl Posts: 1, Reputation: 1
    New Member
     
    #2

    Feb 24, 2008, 06:46 AM
    What are the downsides of teeing in to existing 1 3/4" wastepipe rather than breaking through the outside wall and installing a boss connection. It will carry away a sink and a bath and possibly a shower 's waste
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #3

    Feb 24, 2008, 06:58 AM
    Is there a simple way to convert the toilet drain to something with a p-trap without having to bust up and remove the concrete? Is there some type of adapter on the market for this?
    Sorry Ben! Get out the jackhammer because you're going to hafta bust cement up from wherever you're draining to back to the shower trap and raiser. You can't use a toilet rough in for a shower unless you reduce down to 2". A better way would be to connect to the sink drain,( if it's 2") and let the sink vent service the new shower since you're going to hafta vent it anyway.
    How I would go about it would be to cut a wye or combination wye and eighth bend into the sinks drainline to pick up the shower trap and raiser. Now cap off the sink stubout in the wall and you're in business. Good luck, Tom
    archibot's Avatar
    archibot Posts: 2, Reputation: 1
    New Member
     
    #4

    May 3, 2009, 03:51 PM
    Tom, thanks for the help. I'm in the same situation, pretty much. So, do I understand you correctly? If we can tap into the sink drain line horizontally above grade, we may be able to do the shower install without concrete demo? Maybe we can build a 4" platform to get the p-trap in there and then connect bust into the wall to connect with a tee at the sink drain (the sink is getting capped and removed.)
    I know this isn't pretty but would it work?
    Thanks,
    Mark

    Quote Originally Posted by speedball1 View Post
    Get out the jackhammer because you're gonna hafta bust cement.... A better way would be to connect to the sink drain,( if it's 2") and let the sink vent service the new shower since you're gonna hafta vent it anyway.
    How I would go about it would be to cut a wye or combination wye and eighth bend into the sinks drainline to pick up the shower trap and raiser. Now cap off the sink stubout in the wall and you're in business. good luck, Tom
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #5

    May 3, 2009, 04:09 PM
    Hey Mark,
    Yeah! It would look pretty funky but if you platform the base so could install a "P" trap and then tie back to to the sink drain in the wall you would be drained and vented. Just cap off the stub-out and leave the vent in place.You're going to be kind of tight with a trap and raiser at one end and a sanitary tee at the other. Could you raise the platform to 6". Regards, Tom
    archibot's Avatar
    archibot Posts: 2, Reputation: 1
    New Member
     
    #6

    May 3, 2009, 08:32 PM
    Cool! 6" is probably doable - only 2" uglier than 4". :D
    I'll let you know if we have success with this.
    Thanks again,
    M

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Remove toilet flange to shorten drain [ 3 Answers ]

I just installed new laminate flooring. I removed ceramic tile and underlayment. Dimensional difference is approx. 3/8". Toilet will not mount flush to floor; need to shorten the drain pipe. Flange is glued to drain from original install. What is the best way to remove the flange?

Permanently Remove Shower Drain [ 2 Answers ]

The master bath currently has a separate shower and tub. I would like to remove the shower and reclaim the space as a closet. How should I cap off the drain after removing the shower?

Remove PVC Shower Drain [ 2 Answers ]

Help, I have removed the shower tray and am having trouble removing the shower drain From the main PVC line can't get a good gripe on the drain. And can't use pipe wrench. Any ideas? Thank you. Flash

Convert toilet waste to shower drain [ 1 Answers ]

I am buying a home where the master bath has his & her toilets. I want to remove one toilet and install a shower in this area. Since the toilet line is already vented, is there any problem with just removing the closet flange and adding a reducing coupler to the 3 or 4 inch wasteline to convert...

Basement drain convert to shower [ 3 Answers ]

Hi all, I am trying to finish off our basement, and I would like to put a shower in place of a cast iron floor drain. I have 3 pictures of the drain as it is right now. I don't care if I use a fiberglass shower pan or if I make a tile shower pan. The floor is already sloped into the drain, but...


View more questions Search