Ask Experts Questions for FREE Help !
Ask

Search:

Type: Posts; User: Stratmando

Search: Search took 0.16 seconds.

  1. Answers
    3
    Views
    111

    If funds aren't readily available, I like to get...

    If funds aren't readily available, I like to get a Drywall bucket full of water, and pour from a good height as fast as toilet can handle, Not Overfill. Many times it will clear a clog. Good Luck
  2. Question: Water leak?

    by Stratmando
    Answers
    21
    Views
    335

    Had a good long answer, and about your Name. Lost...

    Had a good long answer, and about your Name. Lost Text, refuse to rewrite it all. What a Pain? I rarely write that much. Damn

    This text was lost as well, copied so not to repeat my second attempt....
  3. Is it Dot?

    Is it Dot?
  4. Answers
    3
    Views
    128

    Correction, I would get a 4 Wire Dryer Cord and...

    Correction, I would get a 4 Wire Dryer Cord and Receptacle, and have on a 30 Amp Breaker.
  5. Probably a stupid answer. But On works no mater...

    Probably a stupid answer. But On works no mater what the temp is. Auto Comes on when Heat or Cool is selected And temperature is set to operate?

    When set to Cool, Does Compressor Kick in?
  6. Answers
    2
    Views
    91

    If tilting op and out doesn't work, may be a left...

    If tilting op and out doesn't work, may be a left and right release under the drawers, Many squeeze, some you have to pull a small spring loaded piece. Good Luck
  7. Answers
    3
    Views
    128

    If the Outlet has the right angle blade as...

    If the Outlet has the right angle blade as opposed to the straight blade prong, then it is 30 Amp Receptacle, and should not be on a 50 Amp Breaker. New and remodel require 4 wire Plug/Receptacle....
  8. Answers
    12
    Views
    201

    Oh Yeah, The Ground in Your Electrical Boxes Need...

    Oh Yeah, The Ground in Your Electrical Boxes Need a Solid wire for a Ground, No Stranded
  9. Answers
    3
    Views
    94

    Usually just 1 fails, Never seen both at same...

    Usually just 1 fails, Never seen both at same time, if windings of contactor shorted, thermostat would carry a heavier load, would have thought fuse in Air Handler would have gone first. If...
  10. Answers
    12
    Views
    201

    Lot of great answers above, could do this, a Quad...

    Lot of great answers above, could do this, a Quad 30/30 Breaker:

    https://www.ebay.com/i/272886286753?chn=ps
  11. Good Question ma0641, Be careful not to hook up...

    Good Question ma0641, Be careful not to hook up until correct, with the readings you are getting, you may also have reverse polarity. Be sure you have the 120 volts between the hot and neutral, and...
  12. The CH-7 Threw me, Thought it was a Board Number,...

    The CH-7 Threw me, Thought it was a Board Number, Inductors are usually identified by an L?
    Transistors Use a Q as T was already used by Transformers which came out long before.
    ...
  13. Answers
    2
    Views
    101

    With regular dimmers, you can only use 1, Another...

    With regular dimmers, you can only use 1, Another type mentioned was on another post.
    Insteon 2477D works well, need 2, can have as many as you want, They Make a Hub that allows control by App/phone?
  14. Answers
    3
    Views
    142

    Not the cheapest, but you could buy a couple of...

    Not the cheapest, but you could buy a couple of 20 Amp Breakers, Maybe around $6 each, and if a working one fails, you already have a breaker, just need to swap the wire.
  15. Answers
    1
    Views
    111

    Not the cheapest, but you could buy a couple of...

    Not the cheapest, but you could buy a couple of 20 Amp Breakers, Maybe around $6 each, and if a working one fails, you already have a breaker, just need to swap the wire.
  16. https://www.google.com/search?q=mailmate+SPL-1209M...

    https://www.google.com/search?q=mailmate+SPL-1209M3+circuit+board&rls=com.microsoft:en-US:IE-Address&source=lnms&tbm=isch&sa=X&ved=0ahUKEwjqmJ7ntu_YAhUBZKwKHbiHCwYQ_AUICygC&biw=1366&bih=638&dpr=0.75#i...
  17. I can usually read resistors, But can't read ALL...

    I can usually read resistors, But can't read ALL Black. Don't know anyone who can, I f you know someone else has one, maybe open it up. Going to see if I can Google the board and see an image and...
  18. Or underground and Transformer?

    Or underground and Transformer?
  19. If your phone is in a weak area in house, you may...

    If your phone is in a weak area in house, you may not receive text until you get a decent signal, then all at once. Wonder if similar to that?
    Do you usually have WiFi On on phone in house?
  20. Answers
    8
    Views
    205

    If reset is not clicking, it may have already...

    If reset is not clicking, it may have already been reset, or didn't trip? The way I like to troubleshoot a water heater is from top to bottom following the voltage, if voltage to element, then...
  21. Answers
    3
    Views
    192

    Can you give models of the equipment, You may...

    Can you give models of the equipment, You may need to do a series/parallel with the speakers to maintain the Impedance.
    Need Impedance of Speakers and Amps Impedance.
  22. Transformers will Hum, You don't have to do all...

    Transformers will Hum, You don't have to do all this, but would either tighten on screws, or connect wires together and have a short pigtail to the receptacle. Backwiring is a Bad thing. Lazy.
    You...
  23. I would try turning off breaker, turn on after...

    I would try turning off breaker, turn on after maybe 10? Seconds? May be Confused
  24. Answers
    10
    Views
    315

    Good Deal, I run into a Lot of bad wiring...

    Good Deal, I run into a Lot of bad wiring techniques about every day it seems.
  25. Answers
    10
    Views
    315

    Any Luck?

    Any Luck?
  26. Check Starter Wire From Battery, Large ground...

    Check Starter Wire From Battery, Large ground from Battery. Measure standing voltage and starting voltage at battery. Then between Battery Ground and Starter Positive, this will help determine if it...
  27. Answers
    10
    Views
    315

    If the NEUTRAL Or Hot Touches Ground it will...

    If the NEUTRAL Or Hot Touches Ground it will trip, Are the Light/Fan On Line or Load side of GFI? Some will trip when first applying power, if it doesn't reset, remove load wires, If it still doesn't...
  28. Answers
    1
    Views
    173

    Take a look here:...

    Take a look here:
    https://circuitboardmedics.com/ford-escape-instrument-cluster-repair/
  29. Answers
    1
    Views
    165

    It was Johnny Depp, I think "Once Upon A Time in...

    It was Johnny Depp, I think "Once Upon A Time in Mexico". His friend would have shot him, But Depp was parked in Back and was going that was anyway?
  30. Usually? The Speed and Reversing are 2 different...

    Usually? The Speed and Reversing are 2 different switches? This switch does Speed and reverse?
  31. Do you hear a click from the Door Switch? May be...

    Do you hear a click from the Door Switch? May be bad if no, could still be bad if you do.
  32. Either the Heat wire is shorted, or...

    Either the Heat wire is shorted, or Contactor/Relay Coil is shorted.
    Try removing the low voltage wire at the coil of heat contactor, and try again, if it doesn't blow, it is the relays coil. Good...
  33. Answers
    1
    Views
    264

    Either the Heat wire is shorted, or...

    Either the Heat wire is shorted, or Contactor/Relay Coil is shorted.
    Try removing the low voltage wire at the coil of heat contactor, and try again, if it doesn't blow, it is the relays coil, Maybe...
  34. Answers
    3
    Views
    908

    Does sound like ground issue, can be a body...

    Does sound like ground issue, can be a body connection or at a socket
  35. Answers
    5
    Views
    988

    Usually before putting on blades, you will...

    Usually before putting on blades, you will install the Round piece so the wires go through the hole. Three screws hold it, 2 slotted, install 2 screws, twist piece in place, install 3rd screw to...
  36. Answers
    4
    Views
    199

    The #2 Phillips work on Drywall screws. A #3 is...

    The #2 Phillips work on Drywall screws. A #3 is the size used for Fan Blades. #1 Phillips is smaller. Both bits work in a Magnetic holder. The Longer one is used in quick change holders. No Magnet....
  37. It can help with Navigation in Normal Operations....

    It can help with Navigation in Normal Operations. Can Provide a direction to an Exit in case of a fire, and you are on floor keeping low?
  38. Question: Pot lights

    by Stratmando
    Answers
    3
    Views
    196

    Try bypassing the Dimmer.

    Try bypassing the Dimmer.
  39. Answers
    19
    Views
    7,852

    Although an old post, Problem may reoccur, If a...

    Although an old post, Problem may reoccur, If a Plastic spout, maybe take a hacksaw or multi tool and remove about 2 " back on spout to expose the screw? You lose a spout, but save your copper? Leak?
  40. Yes,...

    Yes, https://www.google.com/search?q=usb+c+to+thunderbold+3&sourceid=ie7&rls=com.microsoft:en-US:IE-Address&ie=&oe=
  41. Answers
    13
    Views
    479

    Does it work now? Just wire for High Voltage, and...

    Does it work now? Just wire for High Voltage, and change breaker to 20 Amps. 2 Pole Switch.
  42. Answers
    3
    Views
    258

    Brakes can drag as well.

    Brakes can drag as well.
  43. Model of Vehicle would be helpful, and what...

    Model of Vehicle would be helpful, and what lights. Can be fuses, switch, or Bulbs/horn. You can apply voltage directly to horn/light to see if they work. Check Voltage to switches. Can be a relay as...
  44. Fr Chuck, Can you clarify "You can't"?

    Fr Chuck,
    Can you clarify "You can't"?
  45. I believe on that truck Turn and stop are the...

    I believe on that truck Turn and stop are the same filament, odd Turn, works but not brake? Sockets on those would lose ground first(what I usually saw)
    Good ma0641 got it.
    If I remember, that Tail...
  46. You should have a shutoff, Correct answers are...

    You should have a shutoff, Correct answers are above. If My shutoff was buried in Debris, from Hurricane or whatever, and needed to shut off. I would get a 1/4 turn ball valve, get some rain or shine...
  47. Answers
    3
    Views
    264

    If no one answers, compare the part numbers of...

    If no one answers, compare the part numbers of both.
  48. Answers
    3
    Views
    236

    It NEEDS to be Mounted on the Sheet Metal(Heater...

    It NEEDS to be Mounted on the Sheet Metal(Heater Duct)so it can open at correct Heat. Some are one time use, some resettable, some automatically reset.
  49. Answers
    9
    Views
    464

    If you have 240 Between a Neutral and a Hot,...

    If you have 240 Between a Neutral and a Hot, sounds like Neutral is connected to a hot. Which means you likely would have 240 between 1 Hot and Neutral/Ground. And the other hot would have zero volts...
  50. Thanks for anyone try to help, Had a Short...

    Thanks for anyone try to help, Had a Short harness from my other truck, Plugged is, all is good. You probably found googling, Would take you Anywhere but a "2003 Ford E250 trailer Wiring colors"
    ...
Results 1 to 50 of 500