    Well stopped working. The pump circuit breaker is on.

    My well stopped working. The pump circuit breaker is on. The system has a Square D pumptrol pressure switch. How do I determine if the pressure switch is bad (no signal to the submirsible pump) or if the pump (145 feet down in the well) has gone bad.
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #2

    Jul 24, 2009, 04:11 AM

    Stu Kenn
    Start your own thread. Piggy backing on someone else's thread only confuses everyone.

    Vinchenzzi
    How big is your tank? What's the cut in and cut out pressures? What's the pressure when the tank is completely empty of water.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #3

    Jul 24, 2009, 05:40 AM
    Quote Originally Posted by Stu Kenn View Post
    My well stopped working. The pump circuit breaker is on. The system has a Square D pumptrol pressure switch. How do I determine if the pressure switch is bad (no signal to the submirsible pump) or if the pump (145 feet down in the well) has gone bad.
    The first thing you must do is check the breaker box to see if you have power to the control box. Let me know what you find. Tom
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #4

    Jul 24, 2009, 05:52 AM

    Stu, remove the grey cover over the switch. Look at the points inside the switch. Are they closed (in contact) or open? If they are closed, and they probably are, then use an emory board to file them. With the power off, pry open each pair, put the emory board between the points, let them close, and give them a few strokes with the emory board. Do this for each set. Then restore power and see if the pump comes on. This does not always work as the contact points don't normally get so corroded as to not allow 220 volts to pass, but it's worth a try.

    Is your pump in the well or above ground?

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

Circuit breaker tripping on electric well pump [ 9 Answers ]

I have an electric well pump which trips the circuit breaker. The pump does not seem to work. I can reset the breaker but it trips again after five minutes or so. Do I have a pump problem or an electrical problem?

Why my circuit breaker keeps tripping in a submersible water pump? [ 13 Answers ]

We live in the lower Hudson Valley of New York State where currently we're getting lots of rain. Is it possible that something happened to the wiring causing a short circuit? Water pump will trip 20-25 seconds immediately after being reset. Right afterward, it will trip again within 10-15...

Water Pump Circuit Breaker [ 3 Answers ]

When I was taking a shower at my cabin, my water shut off. I went to the circuit breaker and it had tripped. I could not get in back on initially. When I did turn it back on the pump still would not turn on. What happened? The pump is only 2 years old. Thanks, Zelly

110 outlet stops working, NOT tripping any circuit breaker. [ 1 Answers ]

I have a 220 outlet three feet from a 110 outlet. When I am using a clothes washer on the 110, it goes dead after a while (10-30 minutes). No breaker is tripped. When I turn on the 220 clothes dryer, the 110 washer restarts from where it left off.

Well Troll 202 pump has stopped working [ 18 Answers ]

One day we forgot to turnoff the faucet while watering the lawn and therefore emptied out the well. After this our well troll 202 seems to have lost all its pressure and therefore we are not getting any water pumped out of the well. It has the gauge and square D pumptrol. I have tried to...


View more questions Search