Ask Experts Questions for FREE Help !
Ask
    vette100's Avatar
    vette100 Posts: 2, Reputation: 1
    New Member
     
    #1

    Mar 31, 2006, 11:31 AM
    Installing a shower trap in the basement
    Hello,

    This is my first post.

    When I purchase my house a full bath was roughed into the basement.

    I am in the process of installing a shower base in my basement.

    The builder roughed in the shower as follows
    - 6 inch PVC pipe straight into the concete
    - inside the center of the 6 inch pipe is a 2 1/2 inch PVC drain pipe for the shower
    - the 2 1/4 drain pipe is connected to a 4 inch 90 about 3 feet down into the concrete.

    Based on what I see there is no trap for the shower. I assume the purpose of the 6 inch pipe that surrounds the 2 1/2 drain is to give enough room to install a trap.

    Because the 2 1/2 drain pipe runs vertical I am assuming I need to install a S-trap. Put I don't think I have enough room.

    Can anyone give me some advice on the proper way to install the trap. Are there any other types of traps I should be using? Thanks
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Mar 31, 2006, 11:58 AM
    "The 2 1/4 drain pipe is connected to a 4 inch 90 about 3 feet down into the concrete. Because the 2 1/2 drain pipe runs vertical I am assuming I need to install a S-trap. Put I don't think I have enough room"

    First off, "S" traps are outlawed. Are you sure he didn't leave you a vent? If what you're telling me is that the plumber rolled up a 4 X 2 fitting on its back and a 2" raiser is brought up to floor level then you should call the builder back and have him contact the plumbing contractor and have them send a man out at their expense to do the job right. The way you discribe the fittings there's no way they can be used to hook up either a shower or a tub. If the 2" pipe were horizontal instead of vertical you would have a chance to install a "P" trap but the way it sets the floor will have to come up and the 4" fitting cut out and the entire shower rough-in will have to be redone. Good luck and keep me informed. Tom
    vette100's Avatar
    vette100 Posts: 2, Reputation: 1
    New Member
     
    #3

    Mar 31, 2006, 12:03 PM
    Thanks for your help. I am going to call the builder.

    Thanks again. Mark

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

Installing new shower in basement, no drain [ 4 Answers ]

We are going to put a corner shower stall in our basement bathroom which currently only has a sink and a toilet. There is no drain where we want to put the shower. Do we have to break up the concrete and put a drain in the floor and then run pipes over to the toilet or sink drain, or is there any...

Installing a Basement Shower Stall [ 3 Answers ]

Hi everyone, I have a finished basement. There is an old double porcelain sink and on the opposite wall a toilet which is in front of the old cast iron lead joined main drain. I would like to install a sink and shower in the bathroom. I had a plumber look at it and he...

Installing shower in unfinished basement [ 1 Answers ]

I'm beginning a project to add a basement bathroom in our house. The house is only two years old and the basement is unfinished with concrete slab. The builder roughed in a drain for the toilet, sink and also the shower. My question is about the shower drain. Currently it is a 2" pvc pipe...

Installing a shower base in the basement [ 17 Answers ]

We bought a home that already had a sewage pump installed in the basement with three drains already installed in the concrete floor that leads to this pump's tank. One was for a toilet (which is covered), another is for a sink (which at present is in use) and the third is a drain pipe (rubber...

Installing a basement shower(?) [ 2 Answers ]

We bought a home that already had a sewage pump installed in the basement with three drains already installed in the concrete floor that leads to this pump's tank. One was for a toilet (which is covered), another is for a sink (which at present is in use) and the third is a drain pipe (rubber...


View more questions Search