Ask Experts Questions for FREE Help !
Ask
    randolph1031's Avatar
    randolph1031 Posts: 2, Reputation: 1
    New Member
     
    #1

    Dec 28, 2009, 08:06 PM
    Have to hit reset button on bottom of control box to get well pump to run
    To get the pump to start I have to hit the rest button on the bottom of control box, the pump will then run as normal fully charging the tank until pressure vale kicks it off, it will run water for quite some time before pressure gets low enough to kick the switch back on but I have to reset the button for it to start again
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #2

    Dec 28, 2009, 09:30 PM

    Check the little pipe leading to the switch to make sure it is not "crudded up". The little lever you are pulling is a safety feature. It turns the switch off if the pressure falls to 10# below the cut in pressure. If your switch is slow cutting back in, it will disable itself and you have to reset it with the lever.

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

Kenmore ultrawash control panel won't reset and no heat dry button keeps blinking [ 0 Answers ]

Some of the buttons on the control panel won't light up at all. If I press normal wash the no heat dry button lights up with it and then I can't press start. No matter what I push (other than drain/cancel) the no heat dry/lock button is on. I've tried unlocking it, turning off the breaker, pushing...

3/4 h.p. Pump control box running 1/2 h.p. Pump? [ 1 Answers ]

Will a 3/4 hp submersible pump control box run a 1/2 hp submersible pump?

Well pump control box [ 2 Answers ]

Our pump turned on and was building pressure, kicked the breaker, and has not restarted. I first changed the breaker, no luck. Then I changed the pressure switch, same result. I'm wondering how to check the control box before spending money on that.

Well Pump Control Box damaged [ 4 Answers ]

Is there a real link between a power outage and my water well control box being damaged during a power outage? If this could be possible how would it happen? What can I visually check in the Control box to tell if the electrical terminal was damaged?:confused:


View more questions Search