Ask Experts Questions for FREE Help !
Ask
    fox113's Avatar
    fox113 Posts: 2, Reputation: 1
    New Member
     
    #1

    Feb 13, 2010, 10:22 AM
    Where is the high limit switch on a luxaire furnace
    Where is the high limit switch on my luxaire furnace so I can reset it. As soon as it calls for heat the led light flashes red four times and the code is limit switch open. Everything starts up the ventor motor and the blower but there is no flame.
    I need heat
    KC13's Avatar
    KC13 Posts: 2,556, Reputation: 99
    Ultra Member
     
    #2

    Feb 13, 2010, 10:34 AM
    There is probably more than one limit switch on the furnace. The primary limit switch is usually near the center of the main cell panel, and is typically auto-resetting. If it is stuck open, tapping the plate between the terminals may cause it to reset, but an underlying overheating condition likely exists (clogged air filter, etc.). See pic 1.

    An auxiliary or roll-out limit switch is typically the manual reset type. See other pics.
    Attached Images
       
    fox113's Avatar
    fox113 Posts: 2, Reputation: 1
    New Member
     
    #3

    Feb 13, 2010, 10:41 AM
    Thank you i will give this a try and i hope it works.

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

I have a luxaire trouble code flashing limit switch open [ 2 Answers ]

The furnace seems to start up small fan starts OK the flame lights then the gas shuts off and the flash code flashes 4 times (limit switch open)??

Why won't my furnace burner ignite I have a Luxaire High efficiency heater [ 1 Answers ]

The heater will come on and only blow cold air

Where is the high limit switch located on a Trane XR80 furnace [ 1 Answers ]

I was told by a Trane technician that either my high limit switch or the fan relay was causing my problems. The relay is on the control board, but where is the high limit switch

Where is the high limit switch located on a Trane XR80 furnace [ 1 Answers ]

My furnace kicks the burner off when the fan starts. After 30 seconds the burner comes back on and then it runs through its cycle pretty much like it's supposed to. I was told by a Trane technician that it could either be the control panel orthe high limit switch. Where is the high limit switch...

Luxaire High Eficiency Gas furnace Pilot goes off [ 8 Answers ]

Hello Experts, I am a new member of this group from New Jersey. I have a Luxaire Gas Furnace about 12 years old. Today all of sudden cold air was coming through the ducts. Blower was on but no flame I saw then turned off the blower and turned on again Pilot came on so did the...


View more questions Search