    Goodman short cycles
    I have a Goodman Furnace 80+ installed by a HVAC Dealer. It's three years old. The problem I am having is when I set the thermostat back at night to 66 degrees and in the morning it sets up to 70 degrees the furnace runs for a short period (5 -10 minutes) then shuts down. Once the draft induced motor shuts down it immediately starts up again. This cycle continues until the furnace has satisfied the thermostat. I do not remember it doing this when first installed. Any explanation would be appreciated.
    KC13's Avatar
    KC13 Posts: 2,556, Reputation: 99
    Ultra Member
     
    #2

    Nov 16, 2009, 04:05 AM
    Check the status LED while this is occurring. Observe the pattern of flashes and compare to label inside access panel.
    jnjbecker's Avatar
    jnjbecker Posts: 1, Reputation: 1
    New Member
     
    #3

    Dec 4, 2009, 10:10 AM
    I have a Goodman GMT090-3A with the same scenario. I've reset the furnace and cleaned the flame sensor but it still does the same thing: Runs for 5minutes then shuts off and recycles. The LED error is four flashes. I called the local HVAC repair guy and he said to try running it with the filter removed and see if it changes anything. I did this and it ran until it hit the thermostat setting. He said this could be caused from using a pleated filter with these furnace units. The pleated filter will restrict too much airflow causing the furnace to over heat, tripping the flame sensor high limit and shutting the furnace down. I'm going to go buy some cheap blue filters.

    You might want to try this and see if it changes your scenario.

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

Oil burner short cycles [ 1 Answers ]

I have a Carlin hot air oil fired system. The burner appears to short cycle when the stat calls for heat. Once the stat calls for heat the burner fires up and runs for a few minutes after the fan comes on. Then the burners shuts down for a few minutes while the fan still runs and fires up again....

Carrier furnace short cycles [ 1 Answers ]

I have a carrier furnace and when I switch to heat on the tstat the inducer fan comes on then the burners ignite then the blower motor comes on, after about 45 seconds or so the blower motor and burners cut off but the inducer fan keeps running and this process starts again in 10 to 15 minutes with...

Short Furnace Running Cycles [ 7 Answers ]

My furnace only runs for 15-30 seconds at a time. It will kick off and then fire up 2 minutes later for about another 30-40 seconds. The desired temperature is maintained but the very short on and off cycles are very annoying. We were told it may be our thermostat so we installed a new one and we...

Goodman GMPN060-3 Blower Cycles [ 2 Answers ]

I have been in my house for 5 years when the thermostat calls for heat, the inducer blower comes on and almost immediately I hear the pressure switch click and then the relay on the main board clicks and the inducer blower goes off. This happens over and over for a couple of minutes and finally...

Furance short cycles [ 2 Answers ]

I have a carrier 8000 furnace model#58ZAV050-08-serial#3395A20997. In the past ten days the furnace cycles through and run for a while then shuts down.I'm not getting any LED codes. The flame sensor looks good, the high pressure switchseems OK,no indication of a cracked exchanger the flames in...


View more questions Search