    Goodman furnace cycles but does not reach set temp
    I have a Goodman 70,000 BTU, up flow gas furnace (GMV950704CXA) with a Honeywell (RTH 7500D) thermostat installed, November 2006. The unit worked fine until outside temperature went into the 20s.

    Unit fires and goes through normal sequence and runs for approximately 7 minutes, then cycles down and shuts off as though the house has reached temperature when in reality it has not. The diagnostic LED flashes 3 times indicating the low fire pressure switch is stuck open. In approximately 3 minutes the unit will again repeat this cycle. Thermostat set to 70 or more doesn’t matter, the house does not warm above 67 degrees. The filter was quite dirty (house under construction) cleaned then replaced, with no improvement. Vent and Flue pipe is new 2” X 20’ with 3 elbows and they exit horizontally through the basement wall. The drain trap is clear and functioning. When the outside temperature rises into the 30s this does not occur. There does not seem to be any obstructions in the intake or flue pipe.
    I intend to get a little more into this on Saturday, any thoughts would be appreciated.
    pamric's Avatar
    pamric Posts: 2, Reputation: 1
    New Member
     
    #2

    Feb 11, 2007, 08:20 PM
    After checking the unit it was found to be over heating. The unit was installed utilizing the existing return duct from around 1952, which is too small to accommodate the high efficiency unit. When there was a call for heat during the extreme cold days, the unit needed to run longer; hence the over heating due to the undersized/ restricted return. As it’s not practical to replace or upgrade the ducts until construction / renovation is complete, slowing the variable speed motor seems to have accomplished a short term fix.
    NorthernHeat's Avatar
    NorthernHeat Posts: 1,455, Reputation: 132
    Ultra Member
     
    #3

    Feb 12, 2007, 04:19 PM
    Woa woa woa. How does lowering the blower speed prevent overheating? This was the diagnostic code "The diagnostic LED flashes 3 times indicating the low fire pressure switch is stuck open"? Is the fresh air for combustion ran to the outside? I have a wild hunch... the higher blower speed was pulling too much air from around the furnace, this was affecting the pressure switch, measure the true vacuum pressure on low fire with different blower speeds.

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

Temp set at 72 but temp won't go above 66 [ 2 Answers ]

We have a Lennox Pulse 21 furnace. Temp is set at 72 but the furnace stops once the temp reaches 66 degrees. Thermostat seems to be working. The seems to be a problem just when it is really cold (0 to 10 degrees).

Goodman Furnace -takes 2 Or 3 Ignition Cycles before Stays Running [ 2 Answers ]

Hi,hope you can help me out.i have a goodman manufacturing forced air furnace that i believe is giving me a warning sign of a future failure.what has happened is in this order,1st one morning the thermostat showed that the furnace was on and it was'nt.turned it off and then back on at the...

Goodman GMPN060-3 Blower Cycles [ 2 Answers ]

I have been in my house for 5 years when the thermostat calls for heat, the inducer blower comes on and almost immediately I hear the pressure switch click and then the relay on the main board clicks and the inducer blower goes off. This happens over and over for a couple of minutes and finally...

Heater doesn't reach temperature set on thermostat [ 1 Answers ]

I've found that although our programmable thermostat is set at 68 degrees the heat only seems to come on when the house gets to 62 degress and then shuts off when it gets to 66 degrees. Is this a problem with the thermostat or the heater? We have just moved into this house and the heater is new but...

Furnace blower cycles with Thermostat off [ 2 Answers ]

Have Goodman Furnace built 1994. Worked fine until about 3 weeks ago. It starts cycling, and the heat icon does not show on the thermostat. I turn the thermostat off, the furnace continues to blow. Last night to verify, took the thermostat off the wall (but still had the furnace plugged in and...


View more questions Search