    Central heating temperature difference 1st floor-basement
    Hello, I have an old house and the gas furnace is just about as old as the house. The problem I have is that the temperature on the first floor is a lot higher than the basement. I did try to close some of the vents on the 1st floor and open the ones in the basement but I still have a big difference.

    Is there something that can be done?. do I need to install something to re-circulate the air?.

    I do not have air conditionning so this might be a good idea to install one. But I would like to use the existing piping (docks). Am I looking at too many things at the same time ?

    Any help would be apreciated.
    semenzato's Avatar
    semenzato Posts: 3, Reputation: 1
    New Member
     
    #2

    Mar 30, 2006, 07:39 AM
    Quote Originally Posted by gabrielmontreal
    Hello, I have an old house and the gas furnace is just about as old as the house. The problem I have is that the temperature on the first floor is a lot higher than the basement. I did try to close some of the vents on the 1st floor and open the ones in the basement but I still have a big difference.

    Is there something that can be done ? ... do I need to install something to re-circulate the air ? ...

    I do not have air conditionning so this might be a good idea to install one. But I would like to use the existing piping (docks). Am I looking at too many things at the same time ?

    Any help would be apreciated.
    You don't say if your furnace has a fan or if it's gravity-based (no fan, uses the fact that hot air is lighter, typical of very old houses). If the latter, then switching to a furnace with a fan will make a huge difference. If you already have a fan, figure out if the ducts from the furnace to the basement are longer/narrower than those to the first floor. That would explain the difference in heating. If the ducts to the basement are shorter (which would seem more logical if the furnace is also in the basement) check if they have any restrictions meant to reduce air flow, and adjust those. If that also fails, you may need to restrict air flow in the ducts to the upper floor as close to the furnace as possible, rather than at the vents. This assumes that you have plenty of flow (possibly too much) to the upper floor. This will be more effective, and quieter, than closing the vents. If the flow is already low, your fan may be undersized.

    If your furnace has a fan, adding air conditioning should be pretty straightforward. If you have that done, adjusting the flow for both A/C and heating will be included in the installation. Otherwise similar observations apply, after noting that the basement may need less A/C than the upper floor, and that some flow adjustment (manual or automatic) may be needed when switching between A/C and heat.

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

Central Air & Heating [ 7 Answers ]

Good Day, I recently changed my thermostat from a White Rogers to a Hunter programmable model 44260. I connected the system myself and now realize that the heat is not coming out of the vents. The fan is blowing but cool air. I have six wires coming out of the wall plus a jumper on the thermostat....

Drained central heating [ 1 Answers ]

I have drained my vented central heating system to clear sludge. The header tank has refilled but the system has not. I have removed the pump which was full of debris but there is no water coming out of the pipe from the header tank to the pump (a drop of eight feet). On loosening the compression...

Central Heating [ 8 Answers ]

Im not sure my central heating is working fine. I bought a new home and I have lived there about 2 yrs but I rarely used my central heating (long enough) over this time. Recently I used my central heating long enough (over 3 hrs) and noted that while the heating is good initially, the air looses...

Add heating system to central air [ 5 Answers ]

Does anyone know if it is possible to add some kind of heating system to my existing central air. We did some remodeling last year and added central air. We have hot water / baseboard heating but it doesn't seem to be enough. I was wondering how big of a deal it would be to add some kind of...


View more questions Search