    Can't find bleeder valves to bleed hot water heat pipes
    We've just bought a 50-year old home with baseboard hot water heating. I know how to bleed pipes and radiators to release air blocks, but I can't find any bleeder valves in the "usual" places at either end of the copper pipes. :rolleyes:

    Sounds silly, I know...

    Would they be located anywhere else along the pipes? Below the floor? Is there another way to get air out of the pipes if they don't have any bleeder valves? Would there be one valve for the entire system--that I just haven't found yet? (How many questions is that?)

    I've always been told to bleed them at the beginning of every heating season.

    Many thanks!

    Ellie
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Nov 20, 2007, 11:30 PM
    Bleeders can be located anywhere including a high air tube in the attic space.
    Unless you have a fitting that has threads you will not be able to bleed by the old crack a thread method. High bleeder lines can also be located in the closet and various other places.
    I have bleeders in my attic space that have auto vents. The auto vents also have a 1/4 inch copper line attached and if the vent sticks open you can tell by the water coming out of the copper tube sticking out of the lower roof vents.
    I am telling you all of this just to show that vents can be any where. You will have to track them down.

    You do not have to bleed your system every year if it has auto vents. Is the system working correctly? If so it might have auto vents but it is good to know where they are located. Remember the higher in the system a vent is the better it will work at trapping air at that location since air rises to the highest spot in the system. Good hunting!
    edwardj's Avatar
    edwardj Posts: 9, Reputation: 1
    New Member
     
    #3

    Oct 14, 2011, 07:46 PM
    From what I read here - I am assuming you have baseboard heat. Many times a contractor will not add bleeder vales on baseboard radiators. The bleeding of air is done primarirly during the onset of cooler weather. This is done by a purge vavle. It will look a little different than a normal valve in the aspect that it will also have a hose connection on it. You open the auto feed valve fully and then run water through system and out the hose. It may have a cock on it to isolate the boiler from the hose conncetion. If not there may be an extra valve installed to do this.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Water shooting out from behind shower hot and cold valves [ 3 Answers ]

When I turn on the shower, water is not making it up to the shower head, rather spraying out from behind the knobs to turn the shower on? Is it just bad gaskets? How should I repair.

Domestic Hot Water Heating Boiler System Rad Valves [ 3 Answers ]

Re hot water boiler heating system,with 3 zone valves,in home.need to know to know about small "automatic"? Vents at ends of rads One was 'leaking']slowly but steadilty.and dripping slowly thro to basement forming small 3 inch mark on floor. 4 years ago these "automatic" valves replaced (from...

Air bleed valves [ 1 Answers ]

When inspecting a boiler, do you test the air bleed valves on the radiators?

Kitchen sink hot and cold water valves [ 2 Answers ]

Help! The hot and cold water coming out of the kitchen sink faucet are never really "hot" and "cold"... always lukewarm-ish. I've tried messing with the valves underneath the sink, but I don't know if they are both supposed to be open all the way or if one should be open and the other closed......

No bleeder valves hwbb [ 2 Answers ]

My house is 5 years old. I have no bleeders on my hot water baseboard heaters. There is a rattle during circulation and it seems to be coming from a Taco 219 swetchek. Is this a bleeder? Is air causing this rattle or could it be something else? This problem does not happen all the time but is...


View more questions Search