    Outlet with reset button doesn't work
    Hi everybody!

    I just found this website on the computer and I'm hoping someone can help me out... I have a situation. The reset button on one of my kitchen outlets doesn't work. By not working, neither button will pop in or out. They are just kind of "there". Now, I have several outlets that aren't working because of that. Unfortunately, one of the outlets is for my refrigerator... :( My question is can I replace that outlet and if so, how do I do it? I have never done any electrical work, but it seems kind of dumb to have to hire an electrician (which is very hard to get ahold of anyway) just to place an outlet.

    I would greatly appreciate any help!

    Thanks in advance!

    Angie
    JohnSnownw's Avatar
    JohnSnownw Posts: 322, Reputation: 51
    Full Member
     
    #2

    Aug 30, 2007, 08:26 AM
    Yes you can replace the outlet. Those are called GFCI outlets. They are relatively easy to replace. Here is a site with a simple tutorial that walks you through the process of replacing the outlet:

    Installing a GFCI Outlet Tutorial
    angiek1's Avatar
    angiek1 Posts: 5, Reputation: 1
    New Member
     
    #3

    Aug 30, 2007, 08:33 AM
    John -

    Thank you so much!! I found the website and I'm printing everything out that I will need. It looks like it shouldn't be too hard. One more question, it says "Make sure that the amp rating of your new GFCI outlet is consistent with the amp rating of the wiring and the breaker or fuse". How do I find out what the "amp rating" is. Like I said I'm totally new to this.

    Angie
    JohnSnownw's Avatar
    JohnSnownw Posts: 322, Reputation: 51
    Full Member
     
    #4

    Aug 30, 2007, 08:39 AM
    Quote Originally Posted by angiek1
    John -

    Thank you so much!!! I found the website and I'm printing everything out that I will need. It looks like it shouldn't be too hard. One more question, it says "Make sure that the amp rating of your new GFCI outlet is consistent with the amp rating of the wiring and the breaker or fuse". How do I find out what the "amp rating" is. Like I said I'm totally new to this.

    Angie
    The current rating is generally indicated on the front of the fuse carrier.

    * Lighting circuits typically use 5 amp fuse wire, but not greater than 10 amp.
    * Socket outlets use 10 amp fuse wire but not greater than 15 amp fuse wire.
    * Large appliances, such as electric stoves, may use a larger size fuse.

    From:

    Electrical Wiring | Safe Living with Electricity | Electrical Safety
    angiek1's Avatar
    angiek1 Posts: 5, Reputation: 1
    New Member
     
    #5

    Aug 30, 2007, 08:43 AM
    See I'm learning something new every day. I never realized what those numbers were for. Thank you so much for the lesson!
    JohnSnownw's Avatar
    JohnSnownw Posts: 322, Reputation: 51
    Full Member
     
    #6

    Aug 30, 2007, 08:55 AM
    Quote Originally Posted by angiek1
    See I'm learning something new every day. I never realized what those numbers were for. Thank you so much for the lesson!
    Glad to help. Just a quick warning, since you are new to this, please please make sure that you have the power turned off to the outlet before you begin. Good Luck!
    angiek1's Avatar
    angiek1 Posts: 5, Reputation: 1
    New Member
     
    #7

    Aug 30, 2007, 09:10 AM
    I certainly will. I see where they advise you to use a circuit tester to verify the power is off and I think I will buy one of them too. I'm certain I know which breaker it is, but I'd rather be safe than sorry!

    I really, really appreciate your help!

    Angie
    KISS's Avatar
    KISS Posts: 12,510, Reputation: 839
    Uber Member
     
    #8

    Aug 30, 2007, 09:54 AM
    Make sure you check the breaker in the fuse box. It may not be the GFCI at all. When the breaker is tripped there is some play when you try to move it to the on position. To reset the breaker, move to off then on. You may have briefly overloaded the circuit. A GFCI won't trip under this condition.
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #9

    Aug 30, 2007, 10:23 AM
    To do simple checks like this you do need some tools. A test light, a meter, or a voltage detector might be the best place to start with. I came across the niftiest gadget for trouble shooting, a voltage detector. They work through the insulation of wires. There are several brands. I have a GB Instruments GVD-505A, less than $15 at Home Depot. Touch it to a hot wire, and the end glows red. Find the doodad that lights it on one side, and not the other, and you have the culprit. You do not have to open up housings and expose electrical contacts. You are looking at where your hand is, not where the meter is. Most people are capable of doing repairs and will get it going and not get hurt if they use a little sense. The voltage detector makes it even easier.

    Only the very oldest houses have fuses except maybe in things like A/C disconnects. Even where there are other fuses, most of them are 15 or 20 amp. I think code now requires replacing fuses panels with breakers.
    angiek1's Avatar
    angiek1 Posts: 5, Reputation: 1
    New Member
     
    #10

    Aug 30, 2007, 10:44 AM
    The breaker was the first thing I checked and it wasn't tripped. I had really hoped it was that, but unfortunately it wasn't.
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #11

    Aug 30, 2007, 03:43 PM
    Some corrections:

    Quote Originally Posted by JohnSnownw
    * Lighting circuits typically use 5 amp fuse wire, but not greater than 10 amp.
    * Socket outlets use 10 amp fuse wire but not greater than 15 amp fuse wire.
    Lighting circuits are minimum 15 amps with #14 wire, may be 20 amps with #12 wire.

    Receptacle circuits in a kitchen all need to be a minimum of 20 amp.


    The GFI may be tripping due to a ground fault it is detecting in any one of the outlets it is protecting.

    Reefers are known to trip GFI devices.

    Consider getting the reefer onto a no- GFI circuit or outlet. GFI is not needed and not recommended.

    Be sure all appliances are unlpugged and try to reset the outlet.

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

Filter reset button for Honeywell Chronotherm IV plus [ 13 Answers ]

I just changed the filter in my furnace, how do I reset my thermostat to make the word "filter" stop blinking. I called the service dept. and they told me to find my users manual! I can't find it. HELP!

Outdoor outlet quit. Reset where? [ 8 Answers ]

Stupid question: Where would the circuit board or switch be for outdoor outlets? We have one outlet in front and one in back and neither one are working. They're both GFCI with no reset/test buttons. The only GFCI outlets we have inside the home is in the kitchen and we've reset it and nothing...

Outside outlet - won't reset - Christmas distress [ 1 Answers ]

Help Made a mistake and left the outside Christmas lights plugged in and it rained for several hours. House is only 3 yrs old however I do not see a GFI reset on either the front or back exterior outlets. No breaker is tripped. How and where do I find the reset for these outlets. (Manufacturer is...

Gas Furnace needs reset button pushed to work [ 1 Answers ]

1983 - Natural Gas - Rheem Furnace Model #RCDA-100C-ER Originally the furnace blower would not come on. I called a technician who pushed a reset button. He mentioned something about the air fuel mixture and that a gust of wind could have tripped the furnace off. Pushing the button worked for...

Reset button keeps needing to be reset [ 2 Answers ]

The reset button on our oil furnace needs to be reset every 10 to 14 days. What can be the problem? We are leaving for the holidays and I'm concerned that we could come home to frozen pipes.


View more questions Search