PDA

View Full Version : Goodman Furnace Model # GMT045-3


topcatii
Aug 17, 2014, 11:51 AM
Im getting a twinning error code on the furnace. I just replaced the board and had to use the wiring diagram on the unit to install the new board, because someone removed the old one and through it away. I have reversed polarity on secondary 24v and main power, also checked it with a meter it's rite. I double checked the wiring to the board and found no problem, any suggestions would be appreciated.

Thanks, Mike

bitters
Aug 17, 2014, 02:08 PM
Reverse the wires on the primary side of the transformer.