View Full Version : Installing tub on a concrete slab
 
 danball
Mar 31, 2007, 06:38 PM
What would I need to have done before the concrete is poured for the floor?
 iamgrowler
Apr 1, 2007, 12:07 AM
Have a drain, vent and trap arm already installed at least six inches below the slab and have a 12x12 buckout for the trap and waste and overflow.
 speedball1
Apr 1, 2007, 05:50 AM
Let me add a bit to the great answer growler gave you.  The trap raiser should be centered 15 1/2" off the side wall and 1 1/2" off the front plate.
There!  Now you have it all.  Good luck,  Tom