Mar 7, 2013, 08:24 AM
Hi,
I have a well pump (not submersible) that pumps water from a shallow well into a 30 gallon Amtrol Well x-Troll bladder tank. Lately I noticed that the pump was coming on too frequently so I emptied the bladder tank of water and checked the air pressure and It was about 10 psi, so I added air to 28 psi (30 psi below the cut on pressure, cut off is 50 psi on 30/50 square D pressure switch) and everything was OK for three days. On day 3 during the evening the pump started to come on every 5 minutes even though no water was being used. I shut off the well pump and this morning I made sure the bladder tank was empty and checked the air pressure- back down to 10 psi! I recharged to 25 psi and all is well again. Do I need a new bladder tank? I know that my tank is not waterlogged because water is not coming out of the air valve. Please help.
I also timed the amount of time that it took to empty the tank when no water was being used and it was about 1.5 hours- I am guessing this is either a leak in the house or a problem with the check valve in my well- does that seem correct? But I guess I need to fix my pump short cycling problem and bladder tank problem before I look into problem #2. Any suggestions on problem #2?
Thank you, Scott from Florida
I have a well pump (not submersible) that pumps water from a shallow well into a 30 gallon Amtrol Well x-Troll bladder tank. Lately I noticed that the pump was coming on too frequently so I emptied the bladder tank of water and checked the air pressure and It was about 10 psi, so I added air to 28 psi (30 psi below the cut on pressure, cut off is 50 psi on 30/50 square D pressure switch) and everything was OK for three days. On day 3 during the evening the pump started to come on every 5 minutes even though no water was being used. I shut off the well pump and this morning I made sure the bladder tank was empty and checked the air pressure- back down to 10 psi! I recharged to 25 psi and all is well again. Do I need a new bladder tank? I know that my tank is not waterlogged because water is not coming out of the air valve. Please help.
I also timed the amount of time that it took to empty the tank when no water was being used and it was about 1.5 hours- I am guessing this is either a leak in the house or a problem with the check valve in my well- does that seem correct? But I guess I need to fix my pump short cycling problem and bladder tank problem before I look into problem #2. Any suggestions on problem #2?
Thank you, Scott from Florida