View Full Version : Kwikot 600 Dual geyser 150 litre
winnmarx
Apr 27, 2012, 06:29 AM
Not getting to desired temp. Changed both element and thermostat. Disconnected ripple box, current direct at DB. Volts at thermostat 215-224v. Still water luke warm. Mark
speedball1
Apr 27, 2012, 06:48 AM
Not getting to desired temp. Changed both element and thermostat. Disconnected ripple box, current direct at DB. Volts at thermostat 215-224v. Still water luke warm. Mark
Are you saying that you have lukewarm water throughout the entire house or just the shower? Does your shower valve have thermostatic control? N Back to you, Tom
winnmarx
Apr 27, 2012, 08:06 AM
That from the main and only geyser that feeds the whole house. Mark
That's the main geyser feeding the whole house, bath, sink, shower, basins
eldon2
Jun 29, 2013, 01:07 PM
Luke warm water -but found the overflow pipe leaking continuosly .Current and voltage -ok .Element ,gasket got geyser blanket ,all piping insulated.Could vacuum breaker be faulty.
eldon2
Jun 29, 2013, 01:08 PM
Luke warm water -but found the overflow pipe leaking continuosly .Current and voltage -ok .Element ,gasket got geyser blanket ,all piping insulated.Could vacuum breaker be faulty.
massplumber2008
Jun 29, 2013, 04:06 PM
Hi Eldon
No, the vacuum breaker has nothing to do with temperature or the overflow pipe leaking... ;)
You need an electrical tester and you first need to test the elements for continuity (disconnect wires from the elements AFTER shutting power). An element without continuity will need to be replaced.
If both elements test correctly then you'll want to replace the upper and lower thermostats as they are super cheap and quick to replace!
Good luck!
Mark