Dennis234
Dec 27, 2010, 09:20 AM
Do I need to hammer out the floor to put in a p trap if the plumbing is roughed in? The drain is where it needs to be.
massplumber2008
Dec 27, 2010, 09:35 AM
HI Dennis... 
 
The PTRAP should be roughed in for a shower.  To check this, cut off any cap to the shower pipe and pour 1/2 gallon of water into the pipe.  Then, take a flashlight and check to see if water remained in the pipe/trap... if so, the PTRAP is in place and you are all set.
 
A tub drain probably wouldn't have the PTRAP installed... just a pipe stubbed into a box.  You would need to determine the rough in as needed and install the PTRAP yourself.
 
The toilet has an integral trap so yoou will only have a pipe stubbed up for it... no PTRAP underground.
 
The sink will obviously have the PTRAP under the sink, so no PTRAP underground here either!
 
Questions?  Let me know... 
 