Log in

View Full Version : Toilet soil pipe is 1/2 in below fin. Tile floor how do I built concrete floor up


keithkk
May 18, 2010, 10:40 AM
I have 2 problems,just had my bathroom floor tiled on top of concrete floor and was going to use a outside 4 in outside flange on a 4in soil pipe. I can fit over soilpipe now but tile under flange bolt down holes have no concrete under them,plus top of soil pipe is 1/2 inch below top of tile ,tile is 1/4 in thick. What is best fix? Build conc. Up and go to inside flange or add extension to soil pipe .

ballengerb1
May 18, 2010, 01:02 PM
You can use an Oatey twist-n-set inside the pipe and then add a flange spacer. Twist-N-SetŪ Cast Iron Replacement Closet Flange :: Oatey.com (http://www.oatey.com/Plumber/Shared/ProductGroupDetail/363/Twist-N-Set%C2%AE+Cast+Iron+Replacement+Closet+Flange.html )

speedball1
May 18, 2010, 05:23 PM
What you're looking for is flange extenders, (see image) found in most big box stores. Good luck, Tom