View Full Version : Foutain pump triping ground fault
munderseth
Jun 6, 2009, 11:24 AM
My fountain has been running for a couple of years and this week it trips the outdoor outlet when I turn it on. The pump runs for around 30 seconds and then trips the GFI
ohb0b
Jun 6, 2009, 11:39 AM
My fountain has been running for a couple of years and this week it trips the outdoor outlet when I turn it on. The pump runs for around 30 seconds and then trips the GFI
The pump motor seal has developed a leak. Replace the motor.
creahands
Jun 6, 2009, 11:49 AM
Plug in something else with motor. Remove plug for pump. If GFI works all right, then pump is bad.
Chuck