How do I prime my water pump every time I prime it the gauge stays at 10 pressures so what do I do?

speedball1
Oct 23, 2008, 03:48 PM
how do i prime my water pump every time i prime it the gauge stays at 10 pressures so what do I do?

To prime a pump, look on top of the impeller housing and find a threaded 1/4" hole with a plug. This could also have a pressure gage installed in the threaded hole. No matter, turn the pump off at the breaker box and remove whatever's in there and fill the impeller housing with water until it runs out of the hole replace the plug or gage and turn the pump back on. If you can't fill the housing up to the top that would indicate a faulty check valve. Good luck, Tom