Log in

View Full Version : Downsizing The Tub Drain


speedball1
Dec 9, 2007, 03:21 PM
TheHouseCoatguy
New Member Join Date: Dec 2007
Posts: 0
Hi there
I c you are online and read a few of your posts.I was hoping you could give your opion on something.
I am renoing a bathroom and am putting the bathtub where the vanity war .my question is can I use the 11/4 sink drain for the tub.I know it should be 11/2 but if I could use this 11/4 it would save me hours in labour .it would be vented and about 4 feet from stack .but would love an experts opion .
Hope to hear from you .
Kevin

Tubs and shower drainhs are nornally roughed a 2 inches to prevent clog and blockages. Anything smaller and you're asking for a clog.
Now, explain to me how a tub that picks up under the floor line can use a lavatory stubout that sets 18 inches off the floor. Regards, Tom

TheHouseCoatguy
Dec 9, 2007, 03:28 PM
The drain from the sink goes into the wall under the floor to the stack.I was goint to cut and cap the sink line then put a 11/4 t under floor to pick up the new tub.I figured it may be OK the old tub was reduced 11/4 from tub to 11/2 p trap .so its about clogs then not flow rate? Would increasing the drain angle help at all?
p.s sorry about the message I didn't relize it was a different search for each topic .
Think I figured it out now.I am not the most computer literate as I should be srry
THCguy

speedball1
Dec 9, 2007, 03:40 PM
No problem for me. I just have to jump around a bit more to answer PMs and E-mails. You can't lay a sanitary tee on its side. Use a wye or a combination wye and eighth bend instead. You can use 1 1/4 to drain your tub but I wouldn't recommend it. If you do I would install a cleanout near the tub trap to be on the safe side. good luck, Tom

TheHouseCoatguy
Dec 9, 2007, 04:10 PM
Cool thanks for the info .
Would increasing the slope help any? Also does it matter where the tapper happens ?I could run 11/2 from tub to about 1 foot from stck where it would have to reduce to 11/4 .I just can't get my hand any further without some major demo.

TheHouseCoatguy
Dec 10, 2007, 07:13 AM
Do the above points make any difference.ie slope?and when tapper happenes? just want to be a sure as I can before I start cutting .

speedball1
Dec 10, 2007, 08:29 AM
cool thanks 4 the info .
would increasing the slope help any? also does it matter where the tapper happens ?i could run 11/2 from tub to about 1 foot from stck where it would have to reduce to 11/4 .i just can't get my hand any further without some major demo.
Increasing the pitch won't prevent clogs. You can try 1 1/4" if nothing else works but I would install a cleanout next to the trap just to be safe. Regards, Tom

TheHouseCoatguy
Dec 10, 2007, 09:15 AM
Thanks tom much appreciated.srry 4 being a pest