Log in

View Full Version : Counter Top Range Wiring


racer57
Nov 29, 2007, 06:10 AM
I am in the process of replacing/updating my wife's counter top electric range. The electrical supply line has three wires - black, white and ground. The pig tail for the range has three wires - black, red, white and ground. What is the proper way to connect these together?

Thanks...

tkrussell
Dec 1, 2007, 07:47 AM
Assuming the black and white delivers 240 volts, connect black/range to black/feed, red/range to white/feed, white and ground from range to ground from the feed.