Log in

View Full Version : Model#f1aa4217bnv temp. limit adjustment


kenroot1
Dec 22, 2014, 01:57 PM
How do I adjust the temp. correctly for hotter water?

talaniman
Dec 22, 2014, 02:26 PM
How to Repair a Glacier Bay Builders Single Handle Pressure Balance Shower Only and Tub/Shower Faucet Models F1AA4217BNV, F1AA4535BNV, F1BA4502CP, 816-635, 814-278 and 476-615 - Faucet Instructions (http://www.faucetinstructions.com/how-to-repair-a-glacier-bay-builders-single-handle-pressure-balance-shower-only-and-tub-shower-faucet-models-f1aa4217bnv,-f1aa4535bnv,-f1ba4502cp.html)

Single-handle Glacier Bay shower faucet, hot/cold reversed - Fixya (http://www.fixya.com/support/t4754241-single_handle_glacier_bay_shower_faucet_)


Behind the handle check to see if it has a dial to take out and replace at a different position this will change the hot and cold. It a anti scald protection device. Don't remove cartridge just adjust dail.

Mark where you start and take out and move a 1/8-1/4 turn at a time and replace til temp desired. It has teeth like a gear you move to adjust temp.