I am installing new water closet in pier and beam home ,#1 can flange be mounted on top of finnished floor or does it need to be on top of sub floor ? #2 vertical drop is 13 1/2 feet from main septic line, what fitting do I need to maintain proper drop ?
speedball1
Jun 26, 2013, 07:00 AM
,#1 can flange be mounted on top of finnished floor or does it need to be on top of sub floor ? on top of the finished floor.
#2 vertical drop is 13 1/2 feet from main septic line, what fitting do I need to maintain proper drop ?
If I understand your question correctly you have a drop of 13.5 feet from the closet bend to the sewer main.
You will maintain 1/4" per foot and use a 1/8th bend to 45 down tom the main where it will be picked up by a upright wye that you will installe in the main. More questions? I'm as close as a click. Good luck, Tom