How do I cap the water supply lines to an unused wetbar sink that has no shut-off valves?
  I know I need to shut-off the water at the main... after that I'm not sure how to proceed. 
  Do I need to install shut-off valves first?
  I have replaced other faucets and installed new dual flow kits in our toilets... so,.  I can follow basic instructions. But, I will need some specific instructions for this project.
 Thank You.
 hkstroud
Aug 17, 2012, 02:05 PM
If copper pipes cut off square and solder on a pipe cap.  If CPVC pipe cut off square and glue on pipe cap.
 
If you do not do soldering, install a compression stop valve and close valve.
 joypulv
Aug 17, 2012, 02:08 PM
Close the main, open faucets below the level of the pipes you are working on to drain water away from your work, cut the 2 pipes, and clean and solder copper end caps on.
 mygirlsdad77
Aug 17, 2012, 02:55 PM
If the lines are still going to be accessible, a couple of 1/2 sharkbite caps would work nicely.  They are push-fit fittings, that merely push on.   There is also a tool to remove them if need be in the future.
 jklassoff
Aug 17, 2012, 03:12 PM
Thank You to All 3 of You.. (Yes, they are copper lines), thanks for the options, will keep you posted.
 speedball1
Aug 17, 2012, 04:33 PM
All great solutions but  Lee came up with the easiest one which was,  
a couple of 1/2 sharkbite caps   Good luck,  Tom
 hkstroud
Aug 17, 2012, 05:56 PM
Well, I would have said that, but I didn't know they made Sharkbite caps.  I should have, Lee is just smarter than I am.