View Full Version : Boiler pilot will not light


paul24
Aug 31, 2011, 08:13 PM
Changed thermal coupling the pilot will not light

mygirlsdad77
Sep 1, 2011, 03:55 PM
May have to remove and clean the pilot orifice. You can start by unhooking the pilot tube from the gas valve, and if you have gas there, you need to clean or replace the orifice. If no gas at pilot connection, then check for gas coming into gas valve.

mygirlsdad77
Sep 1, 2011, 04:06 PM
Not sure why gas valve is tagged in my earlier post. Im not happy about it. Odds are, the gas valve is not the problem.