MSeven
Nov 2, 2010, 10:45 AM
I have a York furnace that the igniter glows, small blower, the gas comes on and I get blue flames for about 3 seconds. The cycle repeats. The main blower does not turn on. I checked to make sure the exhuast was clear and there's no error codes on module. Also, the main blower works in 'fan on' mode.
Joshdta
Nov 2, 2010, 05:02 PM
The flame sensor needs cleaned with steel wool. Opposite side of the igntor
MSeven
Nov 3, 2010, 02:10 PM
Thanks! This worked for me. The sensor is an easily replacable item. Since the unit is 16 years old, it's worth having a new one on hand.
Joshdta
Nov 3, 2010, 06:45 PM
Nope, I have never seen one go bad. Just needs cleaned from time to time.