View Full Version : Copper Pipe 1" OD - 3/4" ID


wjroberts
May 12, 2010, 06:34 PM
I cut the spicket outside my house and to my surprise I see a thick wall copper pipe that I cannot get a fitting for, 1" OD / 3/4" ID.

I have 1" rubber hose to plug with PVC for temporary so I can turn water on. HELP??

cdad
May 12, 2010, 06:42 PM
Are you sure its just 1 pipe and not one inserted into another? That wall thickness sounds large for copper.

wjroberts
May 12, 2010, 06:52 PM
It is copper on the inside and copper on the outside, never seen anything like it in my life. The outside copper pipe is 1" OD. Where did that come from. I have a picture.

hkstroud
May 12, 2010, 06:54 PM
Most likely you cut into a frost proof hose bib. How long was the valve stem you pulled out.

Show picture.

wjroberts
May 12, 2010, 06:59 PM
I am in Florida. I cut it right behind the brass spicket, could not heat it off.

cdad
May 12, 2010, 07:09 PM
Most likely you cut into a frost proof hose bib. How long was the valve stem you pulled out.

Show picture.

Is this what your talking about?

Ref:

Frost Proof Hose Bibs « Home Inspection Blog (http://www.nachi.org/blog/2010/02/frost-proof-hose-bibs/)

wjroberts
May 12, 2010, 07:13 PM
How do I send pic in this?


No it is not that.

Pictures attached I think

hkstroud
May 12, 2010, 07:44 PM
..

KISS
May 12, 2010, 07:49 PM
7/8" OD is a 3/4" copper TUBE. Any burrs on the fitting will not allow the fitting to work.

If you used a tape measure to measure the diameter, go out to the 1" mark for one end. It's difficult, sometimes to get an accurate diameter unless using calipers or a combination square to mark the center of the tube.

Any water in the lines will make it IMPOSSIBLE to remove the fittings.

It doesn't looked brazed, but could be since it's outside.

Tube and pipe have radically different dimensions. Refrigeration tubing is different than tubing. A 7/8" copper elbow bought in a refrigeration supply house is a 3/4" copper fitting bought in a plumbing supply house.

Confusing, isn't it?

I do suspect it's a 3/4 copper fitting (7/8" OD) with burrs, so it won't fit.

wjroberts
May 12, 2010, 07:52 PM
Trust me I got dimensions right, never seen this before.

Milo Dolezal
May 12, 2010, 08:40 PM
Was that hose bib installed over this fitting or did it fit inside ?

How did you get the old hose bib off ?

Most likely, it is 1" x 1" x 1" Tee with one 1" "fit in" end - meaning, 1" coupling should fit over it.

truck 41
May 12, 2010, 09:19 PM
Looks like you cut off right at the hub of a copper tee, you will have to sweat the piece of copper pipe out of the tee, or replace the intire tee.

mygirlsdad77
May 13, 2010, 03:23 PM
yep, looks like a 1x3/4x1 copper tee. Looks like you cut the spigot off flush with the tee fitting, when you needed to unsweat the spigot. So you have outside diameter of a three quarter fitting which is roughly one inch, and an inside diameter of the pipe left in the fitting which is three quarters of an inch. Do as truck says and try to unsweat the piece of pipe left in the fitting, or replace the complete tee. Good luck and let us know how it goes.

CHayn
May 13, 2010, 04:29 PM
kind of looks like a 1x1x3/4 tee to me with a piece of 3/4 copper in it

wjroberts
May 13, 2010, 05:32 PM
Thanks, could not sweat the pipe out, replaced the tee. Thanks for your help everyone.

Milo Dolezal
May 13, 2010, 06:20 PM
Best way to go !