needfixing
Oct 12, 2006, 07:00 PM
I have a Maytag Gas LDG7600aaw dryer, 13yrs old. It recent stopped igniting the burner. When I first looked at it was full of lint and the igniter was working but would just go out with out lighting the gas. I shook the supply line the next time the igniter went on and it ignited the gas. I vacuumed it out and thought everything might be OK, it wasn’t.. As the problem continued I found by tapping the radiant sensor by the igniter it lit the gas. So I replaced the sensor. I checked the thermostats and they checked out OK.
My problem now is the igniter comes on, gas ignites, runs for awhile, but now after it is hot it won’t ignite until it has cooled down. I rechecked the thermostats, still OK. Is the sensor replaced defective? Could it be a coil? I removed the burner, it is chipped on the end but I do not see how that would prevent it from igniting when it is hot, when it ignites cold. Also, are there other heat sensors? The only other thing I can think of is I didn’t put the wires back properly on the thermostat with multi wires, but I do believe I did. Is there a schematic to check this? Thanks
My problem now is the igniter comes on, gas ignites, runs for awhile, but now after it is hot it won’t ignite until it has cooled down. I rechecked the thermostats, still OK. Is the sensor replaced defective? Could it be a coil? I removed the burner, it is chipped on the end but I do not see how that would prevent it from igniting when it is hot, when it ignites cold. Also, are there other heat sensors? The only other thing I can think of is I didn’t put the wires back properly on the thermostat with multi wires, but I do believe I did. Is there a schematic to check this? Thanks