aglasser
Apr 22, 2009, 04:40 PM
House is in CA, built in 1974 using the MWBC setup.
From Main:
1) Has four single pole circuit breakers.
2) Four Hot running into house.
3) Two Neutral running into house.
A) Circuit #2 handles part of Kitchen as well as bedrooms 1 and 2:
-Kitchen ceiling light(switched)
-Two kitchen wall outlets/switches
-Outdoor light just outside of kitchen door(switched).
Each room includes:
-1 wall light (no wall switch-switched at the light itself)
-3 outlets with full load starting at 5pm. TV's, PC's, Monitors, Clock Radios's, DVD players, AND a wall air conditioner (120v/1150W). - Ya, Ouch, this setup is mirrored in room #2 on the same circuit. Double ouch.
Link to layout is:
http://www.pacificmusicpapers.com/AL_LAYOUT_1.pdf
The theory:
I want to run 2 x 12/3 lines from main; One run from Main connecting to room #1, the other run from Main connecting to room #2. I then want to cut off the head of the snake in the kitchen, leaving the kitchen items, mentioned above, the ONLY items on circuit 2.
The snag (avoiding costs):
I want to have the 12/3 run's supply bedroom #1's outlets/light; The RED for the Air Conditioners (120v/1150w) outlet ONLY and the BLACK for the rest of the room.
Duplicate in room #2 using 2nd run of 12/3.
The question:
Can I use single pole switches for this or do I need to use double? And if single, do I need to stagger them on separate legs?
From Main:
1) Has four single pole circuit breakers.
2) Four Hot running into house.
3) Two Neutral running into house.
A) Circuit #2 handles part of Kitchen as well as bedrooms 1 and 2:
-Kitchen ceiling light(switched)
-Two kitchen wall outlets/switches
-Outdoor light just outside of kitchen door(switched).
Each room includes:
-1 wall light (no wall switch-switched at the light itself)
-3 outlets with full load starting at 5pm. TV's, PC's, Monitors, Clock Radios's, DVD players, AND a wall air conditioner (120v/1150W). - Ya, Ouch, this setup is mirrored in room #2 on the same circuit. Double ouch.
Link to layout is:
http://www.pacificmusicpapers.com/AL_LAYOUT_1.pdf
The theory:
I want to run 2 x 12/3 lines from main; One run from Main connecting to room #1, the other run from Main connecting to room #2. I then want to cut off the head of the snake in the kitchen, leaving the kitchen items, mentioned above, the ONLY items on circuit 2.
The snag (avoiding costs):
I want to have the 12/3 run's supply bedroom #1's outlets/light; The RED for the Air Conditioners (120v/1150w) outlet ONLY and the BLACK for the rest of the room.
Duplicate in room #2 using 2nd run of 12/3.
The question:
Can I use single pole switches for this or do I need to use double? And if single, do I need to stagger them on separate legs?