Hdhawk94
Apr 5, 2008, 08:00 AM
What is an integral stop on a pressure balance valve and how do I know if I need one?
speedball1
Apr 5, 2008, 09:01 AM
Integral stops or screwdriver stops are slotted shut off valves located at the point where the valve connects to the supplies. They are there so you don't have to shut the entire house down to service the valve. Regards, tom