    Install Bathtub shut off valve
    Hello!
    We are trying to install a shut off valve as a temporary fix to a broken faucet, not being paid till the first and needing this taken care of. My toddler was in the bathtub when I went to turn off the hot water and the faucet shot off the wall, along with gallons of water like a geiser, we had to shut it off at the main water supply since looking in the access panel we found there was none. We were going to fix it by replacing the seat and the washer, but it's an old house and it needs to be replaced as the seat is coroded in the pipe. My husband was wanting to do a temporary fix to get us through without having to have the main shut off and the valve is still leaking when he has installed it. We can live the two weeks without the hot water for the bathtub but we need the water in the rest of the house and the hotwater for dishes and laundry too! Is their a way to even seal off if necessary the supply while we're waiting for payday?
    iamgrowler's Avatar
    iamgrowler Posts: 1,421, Reputation: 110
    Ultra Member
     
    #2

    Mar 20, 2007, 07:08 AM
    Quote Originally Posted by simplyjen329
    Hello!
    We are trying to install a shut off valve as a temporary fix to a broken faucet, not being paid till the first and needing this taken care of. My toddler was in the bathtub when I went to turn off the hot water and the faucet shot off the wall, along with gallons of water like a geiser, we had to shut it off at the main water supply since looking in the access panel we found there was none. We were going to fix it by replacing the seat and the washer, but it's an old house and it needs to be replaced as the seat is coroded in the pipe. My husband was wanting to do a temporary fix to get us through without having to have the main shut off and the valve is still leaking when he has installed it. We can live the two weeks without the hot water for the bathtub but we need the water in the rest of the house and the hotwater for dishes and laundry too! Is their a way to even seal off if necessary the supply while we're waiting for payday?
    Is the piping for the tub valve accessible in a crawl space or basement?

    If so, you could always cap it off from below with a galvanized cap or plug -- Assuming it's galvanized piping, of course.

    If he needs to cut the pipe to back it out to a fitting, he should make sure both ends will have threads that are easily accessible to make putting it back together later easier.
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #3

    Mar 20, 2007, 07:13 AM
    What kind of pipe do you have? If it is the cream colored CPVC, you have a cheap easy fix maybe even making the hot water semi usable. You will need a CPVC ball valve, a can of primer, a can of cement, and a hacksaw. $10? Cut a section out of the hot water line to fit the valve in. Clean up the ends and follow the directions on the primer and cement cans. If you buy the dual purpose cement, you can use the same can to the PVC on the cold.

    Other types of pipe may be more expensive and require more skill, but will work the same.

    You may have to hunt a little more to find ball valves, but it is worth it. They are easier to use and have drastically fewer leaks. Gate valves have been obsolete since the 70's, but still predominant. After all, they are what grandpappy used. When I was managing a factory with many difficult to control fluids, we scrapped hundreds of them, replacing them with ball valves and in the larger sizes, butterfly valves.

    There is still a place for chromed globe valves, out where they show.
    simplyjen329's Avatar
    simplyjen329 Posts: 2, Reputation: 1
    New Member
     
    #4

    Mar 20, 2007, 07:24 AM
    Quote Originally Posted by labman
    What kind of pipe do you have? If it is the cream colored CPVC, you have a cheap easy fix maybe even making the hot water semi usable. You will need a CPVC ball valve, a can of primer, a can of cement, and a hacksaw. $10? Cut a section out of the hot water line to fit the valve in. Clean up the ends and follow the directions on the primer and cement cans. If you buy the dual purpose cement, you can use the same can to the PVC on the cold.

    Other types of pipe may be more expensive and require more skill, but will work the same.

    You may have to hunt a little more to find ball valves, but it is worth it. They are easier to use and have drastically fewer leaks. Gate valves have been obsolete since the 70's, but still predominant. After all, they are what grandpappy used. When I was managing a factory with many difficult to control fluids, we scrapped hundreds of them, replacing them with ball valves and in the larger sizes, butterfly valves.

    There is still a place for chromed globe valves, out where they show.
    Thank you, they are Copper pipes and not threaded, we were shocked when checking the access panel that there wasn't a shut off and since we don't have a basement it still leaves us wondering, he did try a ball valve but we had jbweld and it wasn't working for preventing the leak, so, he was going to try to solder but didn't know he needed the foux for a bonding agent, should that work or should I just refer him to the cement. We've come to the conclusion that we'll need to replace the piping since the cold water seems to not want to shut completely off now either, we were just trying a pacifier till payday ;)
    iamgrowler's Avatar
    iamgrowler Posts: 1,421, Reputation: 110
    Ultra Member
     
    #5

    Mar 20, 2007, 07:32 AM
    Quote Originally Posted by simplyjen329
    Thank you, they are Copper pipes and not threaded, we were shocked when checking the access panel that there wasn't a shut off and since we don't have a basement it still leaves us wondering, he did try a ball valve but we had jbweld and it wasnt working for preventing the leak, so, he was going to try to solder but didn't know he needed the foux for a bonding agent, should that work or should I just refer him to the cement.? We've come to the conclusion that we'll need to replace the piping since the cold water seems to not want to shut completely off now either, we were just trying a pacifier till payday ;)
    If it's copper tubing and you're looking for the least expensive way to shut it off until payday, install compression stops or compression ball valves for the time being.
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #6

    Mar 20, 2007, 08:15 AM
    Many people lack the skill to solder copper. When I installed a new faucet in my kitchen last summer, the new one required shortening the copper lines. I have enough trouble doing copper out where I have room, let alone working in tight places. I cut a good chunk of the copper lines off and used CPVC compression unions to adapt to CPVC, a ball valve, more CPVC, and finally a female threaded adapter to the faucet. PVC is larger then copper, so I used the more expensive CPVC for the cold too.

    If you lack plumbing experience, don't count on getting good, tight metal compression joints.
    doug238's Avatar
    doug238 Posts: 1,560, Reputation: 62
    Ultra Member
     
    #7

    Mar 20, 2007, 08:31 PM
    Do not use cpvc dresser couples. Use all brass or the newer 'sharkbite' fittings and threaded valves. What growler said was the best way.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Leaking Water Shut Off Valve [ 4 Answers ]

The main water shut off valve inside the house is leaking. How do I shut off the valve "outside" the house so we can work on fixing this? The house is 16 yrs old. This is the original valve. Would you estimate that this is a simple washer problem? Or is this best left to a professional...

How do I install a hot and cold valve stem for a bathtub? [ 8 Answers ]

I need to know if anyone can send me the steps for installing hot and cold valve stems for a bathtub and if you can send a diagram of a normal bathtub bathtub and what each part is so I can help my brother-in-law and sister get their bathtub fixed. Please respond as soon as you can. Thanks.

Shut off valve not working! [ 34 Answers ]

Hi: I am trying to fix a leaky compression faucet. I have turned off the shut off valve for the cold water under the sink so the when the handle for the cold water of the compression faucet is turned, there is no water as expected. However, even if I turn off the shut off valve for the hot...

Where's toilet shut off valve? [ 1 Answers ]

I cannot find a valve to shut off my constantly running toilet, till the plumber can arrive. Every other place I've lived has had a separate shutoff valve for each toilet, sink, etc. I've looked in, under & around the back of the tank, but there is no valve on the pipe in the bathroom. I've also...

Water Shut-off Valve [ 1 Answers ]

I am attempting to replace the valve supplying water to the toilet water tank, but am unable to unscrew it. It turns, but it does not come off. What can I do? Need help ASAP! Thank you!


View more questions Search