What is a normal water level in an ejector pit?

Asked Nov 6, 2010, 02:27 PM — 4 Answers
Our ejector pit has water in it up to about 6" from the top. It still turns on, but occasionally a drain flowing into it from the basement will back up with water and create a pool of standing water in the basement.

When it gets to that, if I gently shake the pipe from the ejector pump it usually turns on and drains the water, but it seems like more of the water in the pit should be draining than actually is. Any thoughts?

4 Answers
massplumber2008's Avatar
massplumber2008 Posts: 9,247, Reputation: 4637
Plumbing Expert
 
#2

Nov 6, 2010, 02:47 PM


Hi Ag...

Yeah, water shouldn't be that high in a pit...ever.

You'll need to open the pit up and see what is hanging up on the float mechanism. Here, take some bleach and flush it down a toilet many times to clear the ejector pit of most of the real nasty stuff and kind of deodorize the pit. Wait for the pump to come on a final time and then open the pit up to see if anything is stuck on the float mechanism...if so, clear and set the pump back in place.

Seal the pit up with a new seal kit and add a little silicone (flexible) caulking at all pipes as they meet the ejector lid. Test and hopefully you're all set...

Now, this drain flowing into the ejector pit...is it a TRAPPED pipe? If not, then sewer gasses from the ejector system are escaping into your home...not good!

Questions? Let us know...

Mark
Helpful  (1)
ag1000's Avatar
ag1000 Posts: 2, Reputation: 10
Junior Member
 
#3

Nov 6, 2010, 07:36 PM
Thanks...I'll try clearing the float mechanism. The drain has a water trap so I don't think there are any gases or anything. Even when the water backs out of the drain it seems relatively clear/clean. It looks like the water is backing up from the furnace hoses that drain into it. For some reason those weren't drained into the pit directly; only been in the house for a couple years.
Helpful
Milo Dolezal's Avatar
Milo Dolezal Posts: 5,600, Reputation: 1873
Plumbing Expert
 
#4

Nov 6, 2010, 11:00 PM


In addition to Mark's excellent advice: make sure your check valve works. Faulty check valve will allow sewer to drain back to the pit. Also, set pump on couple of bricks to keep it above the bottom.
Helpful
speedball1's Avatar
speedball1 Posts: 25,069, Reputation: 8939
Senior Plumbing Expert
 
#5

Nov 7, 2010, 05:32 AM


Ejector pumps come in several types, (see images) which one do you have? Let me know, Tom
Attached Images
   
__________________
speedball1 is a veteran expert from AskMe.com.
If you would like to tip me please click on my name and profile and if my answer helped, please click on "AGREE/DISAGREE and add a comment Thanks!
Helpful

Not your question? Ask your question View similar questions

 
Thread Tools Search this Thread
Search this Thread:

Advanced Search

Add your answer here.

Remove Text Formatting

Undo
Redo
 
Decrease Size
Increase Size
Bold
Italic
Underline
Align Left
Align Center
Align Right
Ordered List
Unordered List
Decrease Indent
Increase Indent
Insert Email Link
Wrap [QUOTE] tags around selected text
Wrap [CODE] tags around selected text
Wrap [HTML] tags around selected text
Wrap [PHP] tags around selected text
Wrap [YOUTUBE] tags around selected text
Notification Type:



Check out some similar questions!

Can a sump pit be turned in to an ejector pit? Or will I have overflow problems? [ 4 Answers ]

My brother refinished my basement including a bathroom. He used one of my sump pits as an ejector pit. I am told that the furnace, water softner & washer also drain into this pit. However since the bathroom has been finished about 4x a year I get water from the pit or drain in the furnace room. I...

Ground water in ejector pit [ 0 Answers ]

House has sump pump & ejector pump. Only connection to ejector pump is water softener (no basement bathroom). Ejector pump runs routinely, but sump pump very rarely runs. City water department tested recently, advised that we have a leak into the pit (did not open pit, though) and mentioned...

Ejector Pit and A/C drainage [ 8 Answers ]

I had a new overhead sewer installed including an ejector pump for my washer, wash tub, floor drains and A/C and furnace humidifier drainage. The A/C and humidifier condensate drainage line (which is PVC and is run together) runs into the through of the pit cover but is not sealed. It runs through...

Ejector pit [ 1 Answers ]

Hello, selling my house and the "home inspector" suggested to the buyers that the ejector pit should be sealed, mine handles only laundry water and wash tub and is a standard type sump pit with a plastic lift of lid that has a slot half way through for the pipes. What would be the proper way, and...

Toilet Bowl Water level below normal [ 2 Answers ]

In the last few days our toilet bowl water level has dropped to 1/3 of the normal level. When flushed water stay at old level and with in few seconds it drops to 1/3. There is no water leaking on the floor. Any idea what is the problem:confused:


View more Plumbing questions Search