    My water pump will not stop running and doesn't shut off.. new 1 hp craftsman jet
    Our Rural water stopped one day.. pump was toast.I had my plumber hook up a new 1 hp craftsman pump to replace the old one.(same,craftsman) did it just like the inst. Said.. 1" and 1 1/4" to water. Gage on top. Plumbed like picture,primed it and followed inst to start.. it won't get past 40 lbs and it needs 60 to shut off.. seams like the pressure tank is not filling or feels empty also.. it is set at 48 lbs like the book said too...
    My plumber said and I think so too, that we should put a check valve on the 2 main 1" and 1 1/4" pipes before the pump somewhere.. he thinks the pressure is going back to the water source..
    Any rural plumbers out there that can help?
    Thanks!
    Also,. I got my pumphouse ripped apart so I can take a pic if needed.
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #2

    Jun 19, 2011, 06:45 PM

    1. Set your tank at 38#. It should be at 2# below the cut in point, which for you is probably 40#. I say that because most switches have a 20# interval, so yours would be 40 to 60.

    2. If you want to put in a checkvalve, they typically only go on the suction line, not the pressure (return) line. I don't think that's your problem, but it won't hurt to try it.

    3. Make sure your pipe connections are airtight.
    chibearsboy's Avatar
    chibearsboy Posts: 3, Reputation: 1
    New Member
     
    #3

    Jun 19, 2011, 06:58 PM
    OK so would the pressure be going back down to zero too after I turn the pump off,even if the check valve was working on the end of the jet? We only replaced the pump because the jet was working before the pump fried out.and both pumps are craftsman so the old jet shouldn't matter right since it was working before?
    rjh2o's Avatar
    rjh2o Posts: 58, Reputation: 13
    Junior Member
     
    #4

    Jun 20, 2011, 06:05 PM
    Jet pumps can struggle to build 40-60 psi pressure. Typically the highest a jet pump pressure switch should be is 30-50. Most common is 20-40. The old pump may have toasted because there is low water volume coming from the well. If this is the case the system will not build enough head pressure. The impeller may also be bad, causing pump not to build pressure. Try lowering the pressure to 30-50 or put a new switch on and prime the pump while trying to build pressure and keep pump running.
    You have to have check valve on the incoming line only. Make sure there are no air leaks also, seal on pump.
    RJ

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Jet well water pump will not shut off [ 1 Answers ]

Have a shallow dug well. The well ran completely dry. Before I realized it, used all of the water in system including hot water tank.Finally got water in well -2 months later.Had to prime pump to get water. Couldn't gt the primer plug out so had to take hose off the pressure tank to prime. Now...

1/2/HP craftsman jet shalllow well pump only pumps to 25 psi & won't shut off. [ 3 Answers ]

My pump pumps to about 25 psi & won't get any higher. Holds it's prime. PSI switch is per set to 40/60 & new. Air in tank checked around 25 when -0- psi on gage. Pump is maybe 3 years old. Thanks

My water pump will not stop running and doesn't shut off. [ 3 Answers ]

I'm on water catchment and I have a water pump to pump the water to my house. Usually, when I use the shower or toilest, the water pump turns on and brings pressure up to 40/60, then shuts off. This morning, after using the toilet, the pump went on, but kept on running (I had to pull the plug to...

Jet pump will not shut off and pressure does not pass 40 psi [ 1 Answers ]

I have a Myers jet pump with 2 lines coming out. The pump sits approx 20 feet high from the lake source with a 70 foot run to the lake. Pump kicks in at 20 and rises to 40-42 and will not shut off unless I manually do it and the pressure will hold constant at 40 until the water demand brings it...

How can I make my well jet pump to stop running? [ 19 Answers ]

I just install a new CWS100: CWS100 - 1 HP CAST IRON CONVERTIBLE WELL JET PUMPS and Flotec 35 Gallon Capacity Pre-Charged Pressure Tank, Vertical, With 82 Gallon Equivalent . I have install both of them and some how the pump will not stop running even the water is not in use. The gauge will show 29...


View more questions Search