Ask Experts Questions for FREE Help !
Ask
    DaveZ's Avatar
    DaveZ Posts: 4, Reputation: 1
    New Member
     
    #1

    Jun 7, 2006, 03:42 PM
    Water heating system
    I am building a new home (2800 sf each level main and basement) and will be doing a manifold distribution system with PEX piping.

    With the length of the house, I was planning on a two water heater system. Both 50 gal electric plumbed in tandem.

    If this seems feasible, would I just supply the first tank with the cold water and run the outlet (hot water) into the inlet of the second tank?

    Any suggestions would be helpful. Thnxs.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Jun 7, 2006, 04:13 PM
    If this were my call I would divide the house into two sections and supply each section withi its own water heater. I can see no advantage to hooking the heaters in series. That wiuld make the first heater into a storge tank and put the load on number two if this is the one you'll be drawing from.

    Let me give you a option that would save you some money. 50 gallons should handle your home but if capacity is a concern go to a 80 gallon and install a 1/2" return line from the farthest branch back to a recirculating pump.
    This way you would be assured of hot water without the expense of a second heater. Good luck Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Hot water heating system [ 3 Answers ]

Thans for your help in adavance, I have a hot water heating system boiler with a red pump at the side of the boiler. I would like to know does the pump pushes the water through the System.or pull the water back to the boiler.:rolleyes:

Heating system for log home [ 5 Answers ]

We are in the process of building a log home. 1. Size of the home is 1796 sq ft. second floor is 534 sq ft. catheral ceiling, home will be on full basement. 2. planning to use propeane for heat. And will have central air. 3. What would to the best size propane heat unit and central air...

Burping heating system [ 5 Answers ]

Last month I had several visits from my oil service people because of no heat in one of my zones (oil-fired, hot water, 3-Zone system). The solution was to bleed the system until the line essentially burped. Since those visits I've had to burp the lines myself (watched the techs carefully when they...

Water central heating system loses pressure [ 5 Answers ]

The central heating system in my 50 year old home seems to be losing water pressure. We thought it might be due to some pipes that were running in a concrete slab and had leaked. We bypassed that, but now the pressure is still not holding. We see no leaks anywhere. Any ideas?