Home > Home & Garden > Plumbing   »   Home Water Regualtor?

 
Question Tools Search this Question Display Modes
Question
 
 
#1  
Old Feb 7, 2008, 12:07 PM
Cybertrout
New Member
Cybertrout is offline
 
Join Date: Feb 2008
Posts: 3
Cybertrout See this member's comment history on his/her Profile page.
Home Water Regualtor?

Our home is nine years old. Last week the water pressure in the house began to fluctuate while being used. The pipes now make a mild rattling or vibrating noise when water is flowing. Also the water supply in the house actually shut-off for about two hours during the day and then returned. The water shutting off for over an hour during the day happened again four days later.

I was told that the problem is probably the water regulator valve under the house, and that I could replace it myself.

Any comments or thoughts regarding this issue would be appreciated.

Thank You

Reply With Quote
 
     

Answers
 
 
Old Feb 7, 2008, 12:20 PM   #2  
massplumber2008
Plumbing Expert
massplumber2008 is offline
 
massplumber2008's Avatar
 
Join Date: Jan 2008
Location: Boston, Massachusetts
Posts: 2,743
massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.
The pressure regulator valve...? The pressure reducing valve...? Which one....? Let us know the type of pipe...the size of pipe as well. Do you know how to solder...? Get back to us...

Does this valve have a union fitting on one side...both sides...??
  Reply With Quote
 
     
 
 
Old Feb 7, 2008, 12:29 PM   #3  
KeepItSimpleStupid
Engineering & Electronics Expert
KeepItSimpleStupid is offline
 
KeepItSimpleStupid's Avatar
 
Join Date: Aug 2007
Posts: 4,281
KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.KeepItSimpleStupid See this member's comment history on his/her Profile page.
Most houses don't have one, but some need them.
  Reply With Quote
 
     
 
 
Old Feb 7, 2008, 01:41 PM   #4  
Cybertrout
New Member
Cybertrout is offline
 
Join Date: Feb 2008
Posts: 3
Cybertrout See this member's comment history on his/her Profile page.
The water supply line under the house is 3/4" copper pipe and the valve has union joints on both sides. Unable to read the metal tag on the valve to give a brand name. The water main from the street has pressure over 100lbs so all of the homes around here (Carson City, Nv.) have regulators and they are set at 50lbs.

Thank You
  Reply With Quote
 
     
 
 
Old Feb 7, 2008, 02:45 PM   #5  
massplumber2008
Plumbing Expert
massplumber2008 is offline
 
massplumber2008's Avatar
 
Join Date: Jan 2008
Location: Boston, Massachusetts
Posts: 2,743
massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.
Then I would shut the water main, remove the pressure reducing valve, take to shop/bench area in basement and see if you can remove the strainer assembly on bottom...if can remove strainer, then do so and replace and try it out again. If that does not fix then you must rmove valve, take to nearest plumbing supply house and ask for replacement 3/4" copper x copper, pressure reducing valve (100psi to 50psi range or similar).

You will not be able to match up union ends...(YOU WISH!!) so you will need to cut into the 3/4" copper pipe and install it. Once installed will need to confirm pressure....may even want to increase your pressure a bit...so save instructions that come with valve!! To confirm pressure, home supply stores sell a pressure gauge on a female hose fitting so you can hook to outside faucet and take a reading...purchase this along with the following:

Get a mappgas torch at home supply store (about 35 dollars), flux, flux brush, sandcloth, 3/4" cleaning brush and 1lb lead free solder on a roll..then get back to us and we will help from there.

Comments on this post
Cybertrout agrees: Absolutely correct!
  Reply With Quote
 
     
 
 
Old Feb 8, 2008, 02:14 PM   #6  
Cybertrout
New Member
Cybertrout is offline
 
Join Date: Feb 2008
Posts: 3
Cybertrout See this member's comment history on his/her Profile page.
Massplumber2008:

Thanks so much for your input. I purchased a Watts brand regulator and was able to install it this afternoon. And you were correct, the union ends did not match. I had to cut both sides in order to make the connection, but that was not a big deal once I got started.

Water now flows with good pressure and no noise in the pipes. Thanks again!
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
Winterization of a home having well water rayso Plumbing 2 Feb 1, 2008 04:46 AM
home water has odor Djudish Plumbing 2 Oct 11, 2007 06:21 PM
Need water in moble home General Snafu Plumbing 7 Jun 4, 2007 09:00 AM
No water pressure in our home! jeffsnavely Plumbing 2 Nov 20, 2006 07:37 PM
Home water pressure Indiana_guy Plumbing 2 Jul 7, 2005 06:05 AM