Home > Home & Garden > Plumbing   »   vinyl tubing for plumbing

 
Thread Tools Search this Thread Display Modes
Question
 
 
#1  
Old Feb 17, 2006, 08:58 AM
tmeyer01
Junior Member
tmeyer01 is offline
 
Join Date: Nov 2005
Location: Minnesota
Posts: 57
tmeyer01 See this member's comment history on his/her Profile page.
vinyl tubing for plumbing

The water line for my outdoor hose runs just under the I-beams of my basement ceiling. It is currently 3/4" copper. I want to put that into the ceiling so I can finish the basement off. I found 3/4" clear flexible vinyl tubing at the home improvement store that can be put through the holes in each I-beam so it is above the ceiling. I have attached that to the copper line on each end with a copper joint peice and a hose clamp. I turned the water on and left it overnight. I don't have any leaks or anything and the tubing seems to be working. Is this a sufficient resolution for this application or will it not last?

Thanks,

Reply With Quote
 
     

Answers
 
 
Old Feb 17, 2006, 09:50 AM   #2  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,983
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Your installation should last as long as the hose clamp which will out last both of us. Cheers. Tom
  Reply With Quote
 
     
 
 
Old Feb 18, 2006, 06:50 PM   #3  
Junior Member
tmeyer01 is offline
 
Join Date: Nov 2005
Location: Minnesota
Posts: 57
tmeyer01 See this member's comment history on his/her Profile page.
I just realized today that there are two different strengths of vinyl tubing available. The stuff I used is only rated for 35 PSI. Will that be sufficient over a long time period? I'm just worried it may expand and rupture at the end where it connects back to the copper line. I have it hooked up and had the water back on for 2 days now and it is fine so far.
  Reply With Quote
 
     
 
 
Old Feb 19, 2006, 05:23 AM   #4  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,983
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Quote:
Originally Posted by tmeyer01
I just realized today that there are two different strengths of vinyl tubing available. The stuff I used is only rated for 35 PSI. Will that be sufficient over a long time period? I'm just worried it may expand and rupture at the end where it connects back to the copper line. I have it hooked up and had the water back on for 2 days now and it is fine so far.
Better safe then sorry. I would replace the tubing with one that has a higher PSI rating. regards. tom
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
How do I choose the right vinyl siding?
(2 replies)
Looking for a good set of tubing cutters
(1 replies)
vinyl flooring
(2 replies)
Squeaky vinyl flooring
(0 replies)
linoleum v vinyl?
(0 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 09:41 AM.