Ask Experts Questions for FREE Help !
Ask
    awp's Avatar
    awp Posts: 5, Reputation: 1
    New Member
     
    #1

    Jul 3, 2004, 11:38 PM
    Vent Stack Leaking
    Our house, built in 1988, has a leak in its vent stack where one vent line tees into the vertical "main" vent before the main vent goes through the roof. The leaking tee is about 6 to 8 feet below the roof.

    Normally there is no problem with the vent stack (no smells, etc.), but when we get a heavy rain, there is water leaking through a seam in the drywall in the upstairs hallway. During a recent rain, I went into the attic, found the leaky tee and wrapped it in electrical tape. This stopped the leak, and the hallway wall dried up.

    After the weather turned nice again, I ventured onto the roof and ran a 20 foot snake down the vent stack but didn't encounter any obstruction.

    What are your thoughts on putting a couple of 90 degree street elbows together to form an inverted U on the vent stack outside to keep rain and other debris from getting in the vent?

    I know I should find the root cause of the water build-up in the vent stack but, other than the leaky tee, there don't seem to be any problems with the vent stack.

    I appreciate your help.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Jul 4, 2004, 05:08 AM
    Vent Stack Leaking
    Knowing the material the pipes are made of would have helped. I would have sugested recaulking the lead joint or a metal epoxy if the pipes were cast iron or grouting the leaky joint with epoxy if PVC or ABS but your idea is unique and would work just fine. Congratulations for coming up with it. Regards and have a happy forth. Tom
    awp's Avatar
    awp Posts: 5, Reputation: 1
    New Member
     
    #3

    Jul 4, 2004, 12:40 PM
    Re: Vent Stack Leaking
    Thank you for your quick reply.

    You're right, I should have mentioned the vent stack is made up of black ABS (?) pipe.

    Actually, the rooftop is a lot easier to get to than the leaky tee in the attic, so I'll try the inverted U and see what happens.

    Thanks again.
    KARKY2's Avatar
    KARKY2 Posts: 1, Reputation: 1
    New Member
     
    #4

    Sep 23, 2007, 10:05 AM
    A rooftop U is not the correct way to repair a broken pipe or joint in your attic.
    What you are forgetting is that if water can leak out , so can sewer gases.
    This is extremely unhealthy and potentially damaging to your attic.
    Fix the joint by either replacing the pipe section or re-sealing the joint where the leak exists.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Possible Blockage Main Stack Vent [ 1 Answers ]

The two toilets and the tub in the upstairs bathrooms are plugged and will not drain or flush. There is a gurgling sound when we flush or try to plunge the toilets. I have been told by a plumber that he thinks the main stack vent is blocked. How can I unstopped or clear the main stack vent? Are...

Vent stack relocation [ 2 Answers ]

I live on the top floor of a three story condo. I am renovating my kitchen and have run into a problem. I want to remove a wall in my kitchen that the sink is on. There is a 3" vent stack going straight up the middle of the wall I want to remove. Is it ok to re-route the vent stack by adding four...

Another Vent Stack Question [ 1 Answers ]

I have a vent that runs from my middle floor bath to the roof. From the bathroom it runs down into the basement level garage and into the slab with a cleanout before entering the slab floor. The only items that drain into the line are a toilet and sink. The shower has its own drain and vent. ...

How do I tie into main vent stack? [ 3 Answers ]

Are there any tricks to put a 3" Tee into the main vent stack to add a lavatory? I don't think I can lift the top part of the stack up or push the bottom part of the stack down once I cut it in half but I think I'll need to seperate it by something like 2" and then push it back together to have...

Bathtub Vent Stack [ 2 Answers ]

First let me say this plumbing forum is very informative! Now also let me say that I am not well versed in plumbing lingo so hopefully I will be able to ask my question correctly. We plan to remodel our master bath. Currently our bathroom has a separate room for the lavatory, toilet, and...


View more questions Search