Question
 
 
#1  
Old Sep 16, 2006, 09:39 AM
mwarney
New Member
mwarney is offline
 
Join Date: Sep 2006
Location: New Hampshire
Posts: 26
mwarney See this member's comment history on his/her Profile page.
Vent question - critical distance

I want to install a toilet on the second floor of our house. We have a very small room upstairs in the center of the house which is ideal for an upstairs 1/2 bath. The main 4" vent is on the gable end of the house about 26 feet away from where I want to install the new toilet. My first thought was that I could simply go straight up through the wall behind the toilet into the attic and then across the attic to connect to the main vent 26 feet away. But then I read about "critical distance" for venting purposes. Will my original plan work? Or do I need to go straight up through the roof from my new toilet and have a second vent pipe poking throught the roof?

I guess what has me confused is "Where is the critical distance measured from?" If I have a 4" vent coming out of the roof, can I run horizontally from that vent in the attic to connect to my fixture? Is the distance measured horizontally from my trap that point where the vent stack rises vertically through the roof? Or is it measured horizontally from my trap to a point where I can connect to the venting system as a whole?


Thanks in advance for your help!

Reply With Quote
 
     

Answers
 
 
Old Sep 16, 2006, 10:23 AM   #2  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,992
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
""Where is the critical distance measured from?" If I have a 4" vent coming out of the roof, can I run horizontally from that vent in the attic to connect to my fixture? Is the distance measured horizontally from my trap that point where the vent stack rises vertically through the roof? Or is it measured horizontally from my trap to a point where I can connect to the venting system as a whole?"
It's measured from the trap to the vent as a whole.
By 1/2 bath I'm assuming that you'll be installing a lavatory. Right??
If so the lavatory vent can do up in the attic and revent back into the 4" main vent. The toilet will be wet vented by the lav vent. Critical distance doesn't come into play unless there's no opening to the outside air,(a vent).
Since your lavatory trap is right next to access to outside air,( the vent) it doesn't make any difference how long the horizontal line is to connect to that outside air. Good luck, Tom
  Reply With Quote
 
     
 
 
Old Sep 16, 2006, 10:38 AM   #3  
New Member
mwarney is offline
 
Join Date: Sep 2006
Location: New Hampshire
Posts: 26
mwarney See this member's comment history on his/her Profile page.
Thank you Tom very much for the information! Yes, there will be a lavatory and a toilet. So let me make sure I understand. I will vent the lavatory into the attic connecting to the 4" stack, and vent the toilet into the same (probably 2 inch) vent pipe rising from the lavatory. Is that correct?

Thanks again!
  Reply With Quote
 
     
 
 
Old Sep 16, 2006, 12:08 PM   #4  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,992
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Quote:
Originally Posted by mwarney
Thank you Tom very much for the information! Yes, there will be a lavatory and a toilet. So let me make sure I understand. I will vent the lavatory into the attic connecting to the 4" stack, and vent the toilet into the same (probably 2 inch) vent pipe rising from the lavatory. Is that correct?

Thanks again!
Not quite! You will have a 3" toilet drain line going to the 4" stack. You'll pick uo the lavatory with a 3 X 2" fitting and elbo up 18" to the center of a 2 X 2 x 1 1/2" sanitary tee from the floor. The top of the tee will continue up to the attic where it will revent back into the main vent with a 4X2" inverted tee or wye. The toilet will not require a dedicated vent as it will be wet vented by the lavatory. good luck, Tom
  Reply With Quote
 
     
 
 
Old Sep 16, 2006, 12:53 PM   #5  
New Member
mwarney is offline
 
Join Date: Sep 2006
Location: New Hampshire
Posts: 26
mwarney See this member's comment history on his/her Profile page.
Quote:
Originally Posted by speedball1
Not quite! You will have a 3" toilet drain line going to the 4" stack. You'll pick uo the lavatory with a 3 X 2" fitting and elbo up 18" to the center of a 2 X 2 x 1 1/2" sanitary tee from the floor. The top of the tee will continue up to the attic where it will revent back into the main vent with a 4X2" inverted tee or wye. The toilet will not require a dedicated vent as it will be wet vented by the lavatory. good luck, Tom
Thank you soooo much! Very well explained... I can see it cear as a picture now!
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
Critical distance question for shared vent
(6 replies)
Critical Distance is Pipe Length or Literal Distance?
(2 replies)
vent question
(1 replies)
max distance of vent to toilet
(3 replies)
Critical THinking QUestion?
(0 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 10:32 PM.