    Vanity drain line and water supply
    Tom, I have a couple of questions for you. I am installing a double simk vanity. What is the standard for the drain line coming through the wall, as far as how high off the floor, and how far through the wall should it protrude for the trap adapter etc. same thing for the supply lines coming through the wall, Is there a certain spacing that is required as far as the distance between the lines and how high off the floor etc. Also what type off cucoff valve do you sugest to yous, threaded or compression etc. thanks again for any info. Dave
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Dec 18, 2003, 11:23 AM
    Vanity drain line and water supply
    Hi Dave, Your stubout, (drain) will be 18" off the floor and 3 or 4" out from the finished cabinet wall. Position the stubout a little off center of one of the lav drain and pick up the other lav drain with a wye coming off the stubout . Your supplies will be 18" off the floor and 4" either side from the centerline of the stub out. The shutoffs will be 1/2" X1/4" compression angle stops. Good luck with your remodel, Tom
    DDave's Avatar
    DDave Posts: 24, Reputation: 1
    New Member
     
    #3

    Dec 18, 2003, 01:13 PM
    Re: vanity drain line and water supply
    Tom, thanks for the info. What would be a very good quality brand name of drain hardware to buy for the drain trap and extensions etc. Should I try to stay with 1.5 in. hardware or is 1.25 in. the standard for bathroom sinks? Thanks again Tom. You have been great help! Dave
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    Dec 18, 2003, 04:25 PM
    Re: vanity drain line and water supply
    Hi Dave,   Most any Pop-up Lavatory Drain, except the plastic ones, will do.  The standard is 1 1/4". Your trap will have a nylon gasket to increase the accommendations to 1 1/2".     Tip:  Even if it has a neoprene gasket where the lip of the drain fits the slope of the lavatory I always run about a 1/4" bead of plumbers putty around the lip for insurance.  Regards, Tom  
    DDave's Avatar
    DDave Posts: 24, Reputation: 1
    New Member
     
    #5

    Dec 22, 2003, 08:41 AM
    Vanity drain line and water supply
    Tom, how are you doing. One quick question about my drain. I am installing kitchen height cabinets in my bath room. Is the 18 inch drain height from the floor still OK or should it be higher? Thanks Tom. Dave
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #6

    Dec 22, 2003, 09:29 AM
    Re: vanity drain line and water supply
    Good morning Dave,  18" is  the correct elevation for both kitchen and lavatory stubouts.  Happy Holidays to you and yours.  Tom I should have added that for your shutoff valves that you will need BrassCraft 1/2X1/4X1/4 compression angle stops on your water supplies. That will give you access to a hot and cold supply for each lavatory. Chirstmas is past but have a HAPPY NEW YEAR!! Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Supply line size [ 2 Answers ]

http://home.comcast.net/~lpeery1/images/plumbing.jpg I need to run supply lines for a bar sink, toilet, bath sink all sharing the same wall (3 colds, 2 hots). Should the two horizontal supply lines I bring over off the main 3/4 inch lines be 1/2 inch or 3/4. Thanks, Larry

Vanity Water Lines [ 5 Answers ]

We are having a house built and the plumber ran the water lines up through the floor rather than through the wall. I have never seen this before. Is this common? I am concerned that the lines will not have the strength to support a shutoff valve? Are there any codes related to this issue? ...

Replacing Toilet's Water Supply Line [ 9 Answers ]

My house was built in 1979. I have a leak in the water supply line connecting from the turn-off valve down by the baseboard to the tank. I just replaced the guts of the toilet and when I got ready to turn the water back on, the bendable line was leaking. Evidently the line was bent one too many...

Replaced Main Water Line, Now Shower Line Is Clogged [ 3 Answers ]

We had a leak, so we had the water line and sewage line from the house to the street replaced. Now we have no water in the shower. Some debris most have clogged up the line coming into the shower. All the other lines are fine. My Dad is somewhat of a handyman and wants to fix the problem...

Help -- Leaky stem on toilet supply line! [ 7 Answers ]

Hi: My husband and I are DIY newbies. We just attempted to replace a 70 year old leaky toilet in time for 1st holiday fam visit only to incur new problems. For one, the water supply stem is leaking (right around where knob connects to the stem)! Never done this before. To boot, the tank to our...


View more questions Search