Ask Experts Questions for FREE Help!
Ask    ||    Answer
 
Advanced  
 

Ask QuestionsprogressAnswer QuestionsprogressBuild ReputationprogressBecome an Expert
 
Free Answers in 3 Easy Steps

Register Now
3 Steps

At Ask Me Help Desk you can ask questions in any topic and have them answered for free by our experts. To ask questions or participate in answering them you must register for a free account. By registering you will be able to:
  • Get free answers from experts in any of our 300+ topics.
  • Accept money for answers that you provide.
  • Communicate privately with other members (PM).
  • See fewer ads.

Home > Home & Garden > Plumbing   »   Sudden water loss

 
Thread Tools Search this Thread Display Modes
Question
 
 
#1  
Old Oct 25, 2009, 01:30 PM
bpears
New Member
bpears is offline
 
Join Date: Oct 2009
Posts: 5
bpears See this member's comment history on his/her Profile page.
Sudden water loss

We purchased a fairly new home about a year and a half ago (home built in 2003). Recently (last few weeks), the water pressure frequently weakens and then cuts out completely (both hot and cold water). However, if we turn the water off for just a little bit (1 minute or less) the pressure returns, as if nothing had happened.

We are on a well and have pvc pipes. Typically the water pressure is great, until it acts up and then we know that we are going to lose water completely and then it will come back. Any suggestions on where to start with this problem?

Reply With Quote
 
     

Answers
 
 
Old Oct 26, 2009, 06:05 AM   #2  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,992
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Could it be a lowered water table? The pump lowers the table until it sucks air until the table fills up again. How long is the period that the water's off? What's the bladder tank setting? Back to you, Tom
  Reply With Quote
 
     
 
 
Old Oct 26, 2009, 06:30 AM   #3  
New Member
bpears is offline
 
Join Date: Oct 2009
Posts: 5
bpears See this member's comment history on his/her Profile page.
Tom-

Thank you for your response. The water is only off for a very short period of time, never more than a minute. After a little more searching with the system, it seems as if the switch is not triggering the pump properly. The pump does not turn on until after the pressure in the tank hits 20 psi and does not cut out until the pressure in the tank is almost 80 psi and there seems to be a delay in the switch. The settings on the switch indicate that it is a 40/60 switch, so now we are trying to figure out if this is the switch or the pressure tank. We assume the loss in water is coming from the delay between when the tank empties and when the switch flips to alert the pump that there is no water? any suggestions. Water table should be fine... we are on the east coast and have had significant rain... even during the severe droughts over the past two years, we have had no problems with the water table!

THanks
  Reply With Quote
 
     
 
 
Old Oct 26, 2009, 06:49 AM   #4  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,992
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Your pressure control sounds faulty. that's the first thing I would replace. Or have you been adjusting the two springs in the box? Let me know, Tom
  Reply With Quote
 
     
 
 
Old Oct 26, 2009, 07:40 AM   #5  
New Member
bpears is offline
 
Join Date: Oct 2009
Posts: 5
bpears See this member's comment history on his/her Profile page.
That is definitely where we are starting... and then on to the tank. We have not messed with the springs at all, but might just be safer to just replace the switch. We will go from there and then report back for more help as needed!

Thank you for your help!
  Reply With Quote
 
     
 
 
Old Oct 26, 2009, 04:30 PM   #6  
Senior Member
jlisenbe is offline
 
Join Date: Dec 2005
Posts: 946
jlisenbe See this member's comment history on his/her Profile page.
BP, be sure to replace the little pipe leading to the switch. I'd be willing to bet it's clogged up.

Comments on this post
speedball1 agrees: Good catch!
  Reply With Quote
 
     
 
 
Old Oct 26, 2009, 05:25 PM   #7  
New Member
bpears is offline
 
Join Date: Oct 2009
Posts: 5
bpears See this member's comment history on his/her Profile page.
We have replaced the switch and are still having the same problem (did not clean/replace the pipe -got this message too late). Based on the pressure gauge, the well pump cuts on when the gauge is at 40 psi (with the new switch) and does cut off when the gauge reaches 60 psi; however, the tank is already empty when the gauge reaches 40 psi...so we seem to have a lapse between when the tank is empty and the gauge actually indicates that the tank is empty.

Could this be remedied by just cleaning out/replacing the pipe? Could this be a leak somewhere? Thank you both for your help... we are pretty frustrated and do not want to call a well person for something that could be an easy fix.
  Reply With Quote
 
     
 
 
Old Oct 26, 2009, 08:50 PM   #8  
Senior Member
jlisenbe is offline
 
Join Date: Dec 2005
Posts: 946
jlisenbe See this member's comment history on his/her Profile page.
I'd replace the gauge (cheap) and the little pipe (even cheaper). The most dependable pressure gauge you have is how much water comes out of the faucet. If nothing is coming out, then you have next to no pressure, no matter what the gauge says. It might be sticking on 40#.

BTW, do you have a water filter/softener on this system?

ONe more question. When water is not being used, will the system hold steady pressure?
  Reply With Quote
 
     
 
 
Old Oct 27, 2009, 05:16 AM   #9  
Home Improvement & Construction Expert
hkstroud is offline
 
Join Date: Jan 2008
Location: Alex, VA
Posts: 4,117
hkstroud See this member's comment history on his/her Profile page.hkstroud See this member's comment history on his/her Profile page.hkstroud See this member's comment history on his/her Profile page.hkstroud See this member's comment history on his/her Profile page.
Assuming you have a bladder tank, check the air pressure when the tank is empty.

Turn off pump breakers. Empty all of the water in the tank. Open faucet, if you have a drain at the tank open it. Check air pressure. Pressure should be 38# with tank empty.
  Reply With Quote
 
     
 
 
Old Oct 27, 2009, 06:17 PM   #10  
New Member
bpears is offline
 
Join Date: Oct 2009
Posts: 5
bpears See this member's comment history on his/her Profile page.
thanks to everyone who responded... we replaced the switch and gauge... and the little pipe leading to the switch... and so far so good! The little pipe leading to the switch was completely clogged!

Thank you for your help! Saved us a ton of money!
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
sudden loss of well water
(1 replies)
sudden loss of water pressure
(6 replies)
Sudden loss of water pressure - have well
(1 replies)
Sudden Loss of Water Pressure
(1 replies)
Sudden Water Pressure Loss
(4 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 03:13 PM.