    Submersible well pump won't build enough pressure to kick off?
    WE have recently been losing water pressure so I went to the well house to check it out and we only showing 20 lbs or less on gauge. When I shut breaker off to pump the pressure immediately dropped to zero. I put a new check valve in my line where it come out of the ground. It stoppped the water from going back down the line but my pump won't shut off because it won't build up enough pressure to fill the bladder tank and kick off the pressure switch. There is also a lot of spitting and sputtering whenwe turn the faucet on. Is my pump junk or is my well running dry? The line leading down to the pump is approx. 175 feet deep and when I pulled the pump awhile back it was wet up to about 30 ft on the line.
    jlisenbe's Avatar
    jlisenbe Posts: 5,019, Reputation: 157
    Uber Member
     
    #2

    Mar 4, 2012, 06:17 AM
    How old is the pump? Sounds more like a bad pump to me. Also, is the wellpipe galvanized or PVC?

    It's nice to have a CV at the wellhead, but there should be one right at the pump which is really the only one you need. If that one is bad, and from your description it plainly is, and you have any kind of leak in the wellpipe, then you could be drawing in air each time the pump kicks off.

    Well could be low on water, but from what you describe, that would not seem to be the case.
    thirstyanddry's Avatar
    thirstyanddry Posts: 3, Reputation: 1
    New Member
     
    #3

    Mar 4, 2012, 08:08 PM
    The pump is only about 5 yrs old. When I turn the power on to the pump it won't kick the points in the pressure switch to shut off because it won't build up to the 30 pound shut off pressure.Around 20 pounds is as high is it will go. I even shut off the main valve on the inlet line that leads to my house to make sure I didn't have a leak somewhere. The line in the well casing is the black plastic line that is used in underground applications(PVC). I put a new pressure switch and CV in yesterday with no results.I am wondering if a crack or hole in the line somewhere between the pump and the switch could be the problem. I plan to pull the pump tomorrow but I don't want to replace the pump if I don't need to because it will cost about 500 bucks to replace it and once I install it there is no returning it if it doesn't fix my problem. At the present, I am just using my breaker to get water in the house.I turn it on to get water, and turn it back off as soon as I am done. I am trying to keep from burning up the pump, Not to mention save electricity.I am dreading to see how much my next electric bill is going to be because we were living with this pressure loss for a couple weeks before I had time to investigate and discover the pump wasn't kicking off!
    jlisenbe's Avatar
    jlisenbe Posts: 5,019, Reputation: 157
    Uber Member
     
    #4

    Mar 5, 2012, 03:56 AM
    Should be a CV right above the pump. I'd replace that. Check that well pipe carefully. I'm going to guess you are going to find a problem with the pipe.
    thirstyanddry's Avatar
    thirstyanddry Posts: 3, Reputation: 1
    New Member
     
    #5

    Mar 10, 2012, 03:55 PM
    Thank you for your response. I figured out what was wrong with it by pulling the pump. I left it hooked up to the water line and put it in a barrel of water and turned it on so I could check the line for leaks. There were no leaks in the line so I determined that the problem was with the pump. I tore into the pump and when I disassembled the impeller part of the assembly I discovered that it was completely wore out. It was still functioning but it wouldn't pump enough water to push the pressure up to what I needed. It just so happens that I had another pump that a guy from my church had given me a few years ago but the motor was too small for my well. I done some measuring and luckily everything matched up for me to put my bigger motor on the pump assembly from the smaller one. I got it all put back together and did another barrel test and within 10 seconds I had 50 pounds of pressure! I dropped it back down the well and powered it up and so far, we have had better pressure than we've had for a long time! I got it fixed and it only cost me about 50 bucks for a new CV and a few fittings! God definitely watches out for His kids. I posted this response in hope that somebody else might be able to learn that thing are sometimes easier and less expensive than we think they will be. God Bless
    cknwizdom1x's Avatar
    cknwizdom1x Posts: 2, Reputation: 1
    New Member
     
    #6

    Jun 12, 2012, 05:00 AM
    I had the same problem and you were correct... my pipe was clogged up with debree and small rock from my well. Thank you. You saved me $250. Plus
    A very grateful new fan of folks that make a difference. If you are a father, Happy Father's Day and if your dad is living, thank him for teaching you the caring act of helping others. Again Thank you. Ckwizdom
    cknwizdom1x's Avatar
    cknwizdom1x Posts: 2, Reputation: 1
    New Member
     
    #7

    Jun 12, 2012, 05:09 AM
    I have a filter between my pump and my house that I installed a faucet on to be able to flush out the filter out without having to remove it (the filter). I also installed a fitting in between the pump and the filter that has a lever on it to cut the water on and off allowing me to remove the filter if need be to dump out debree and small rock trapped in the filter, (pvc like you use say in a small pond) so you won't flood you well shed. Once I took the filter off, I opened the faucet and then I opened the fitting and blew out the debree and small rock that was trapped in the pipe between the pump and filter. Worked like a champ. Thank you
    jlisenbe's Avatar
    jlisenbe Posts: 5,019, Reputation: 157
    Uber Member
     
    #8

    Jun 12, 2012, 02:41 PM
    Glad it worked out for you.
    Crunsch's Avatar
    Crunsch Posts: 1, Reputation: 1
    New Member
     
    #9

    May 25, 2013, 02:25 PM
    Sounds like the problems Im having. Now to find out "how" to do this. Im a handyman so... off I go. Thanks for posting---Bless God

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Submersible pump lost pressure [ 1 Answers ]

I have a submersible pump that has lost pressure. It is reading 13 psi. The bladder tank is also not filling and the pump is not shutting off. Please help.

Does shallow well jet pump build air pressure in the bladder or just water pressure? [ 0 Answers ]

My 40/60 3/4hp shallow well jet pump will run continuously and will not build up air pressure in the bladder. The bladder will hold pressure though. I have filled it with air and when I turn on the water it loses its pressure and when the pump kicks on it just keeps running without building the...

SUbmersible pump has trouible to get pressure above 20 PSI [ 0 Answers ]

I have a submersible pump set to cut in at 20 psi and cut out at 40psi. Recently something happened and I cannot get the pressure above 20 psi and thus the pumps stays 'on' all the time unless I turn off the circuit breaker. The pump has no trouble to get the pressure to 20 psi.What can I do?

Low pressure from submersible well pump [ 10 Answers ]

I'll summarize what my situation is and what I've done so far. Pressure tank doesn't fill with water Pressure tank air pressure is 28 PSI Tried installing brand new pressure switch and water pressure gauge Water pressure gauge rose to 26 PSI when I turned the pump breaker back on It stays at...

Submersible pump is working but we can't get pressure to build to the normal 76psi [ 0 Answers ]

We have a well that has been fine for 10 years. The pump that was in there was a 25gallon per minute. We originally installed a pump and it failed right away and was sent back to the manufacturer and it turned out an impeller was installed backwards. They warranty'd it and sent it back to us. ...


View more questions Search