Question
 
 
#1  
Old Apr 2, 2008, 12:58 PM
IamJung2
New Member
IamJung2 is offline
 
Join Date: Apr 2008
Posts: 1
IamJung2 See this member's comment history on his/her Profile page.
sewage pump/ejector pump

My sewage/ejector pump sometimes won't shut itself off. It has gradually gotten worse as time goes by. What could be causing this? Any suggestions appreciated.

Reply With Quote
 
     

Answers
 
 
Old Apr 2, 2008, 02:34 PM   #2  
Home Improvement & Construction Expert
hkstroud is online now
 
Join Date: Jan 2008
Location: Alex, VA
Posts: 4,132
hkstroud See this member's comment history on his/her Profile page.hkstroud See this member's comment history on his/her Profile page.hkstroud See this member's comment history on his/her Profile page.hkstroud See this member's comment history on his/her Profile page.
Check the float mechanism to insure that its is not getting hung up on something.
  Reply With Quote
 
     
 
 
Old Apr 2, 2008, 04:27 PM   #3  
Plumbing Expert
massplumber2008 is offline
 
massplumber2008's Avatar
 
Join Date: Jan 2008
Location: Boston, Massachusetts
Posts: 5,476
massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.massplumber2008 See this member's comment history on his/her Profile page.
Hi guys:

Iamjung...does your pump system have 1 or 2 cords (1 plugs into the back of the other)?

If 2 cords, then may have a "PILL" type float mechanism that is pretty famous for failing over time. It could be getting caught up on something like Harold suggested. It could also have let some water into float mechanism and begun to rot from the inside out. I have replaced many of these over the years.

If have 2 cords, best way to check this is to set water flowing into pit just until pump turns on and pumps pit empty...then shut water flow, disconnect the power supply to pump and float mechanism, disconnect the pump from the check valve (loosen bottom half only!!) and open up ejector pit (1 side of cover only if possible).

Now, pull that pump out of pit, let it drain itself of water a bit.....then carefully plug the pump and the float mechanism back in together...then tilt the pill switch up and down...just like you can picture it working in full basin (on) to empty basin (off).

If fails, or sticks and stays on...found/confirmed the problem. Just go to supply house and they should have a replacement float for you. Reverse steps, install as last installed and should be set.

If this is a single cord sump pump, then maybe that float mechanism at the sump has failed for whatever reason....steps are pretty much the same to check/confirm float arm/mechanism is at fault.

Get back to us with any more questions...Mark

.
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login



Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes
Ask your question or search...



Similar Threads
Sewage Smell in Finished Basement with Ejector Pump
(4 replies)
sewage ejector pump
(2 replies)
sewage ejector pump
(5 replies)
Ejector Pump???
(3 replies)
Sewage Ejector Pump in a Basement
(7 replies)

Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page
Search this Thread

Advanced Search

Bookmarks





Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 08:14 AM.