#1  
Old Oct 28, 2008, 03:42 PM
tm2203
New Member
tm2203 is offline
 
Join Date: Oct 2008
Posts: 3
tm2203 See this member's comment history on his/her Profile page.
Is "s" trap hookup legal?

I just had our kitchen remodeled. When the contractor tried to hook up my new deeper sink, he said the drain was too high. There was water in the bottom of my disposal. I said this was unacceptable, so he cut a hole in the floor and put the drain pipe through the floor, into my basement and over to the main drain. I told him he went from a "p" trap to an "s" trap and I thought this was illegal. There is also no vent. He said this was a legal hook-up as long as it was 6 feet or less to the main drain. The new pipe to the main drain is just under 6 feet. This guy is a licensed plumber, but I don't feel confident about the hookup or his explanation. Can I get some comments? Thanks, I'm a mom who doesn't know much about plumbing.

Reply With Quote
 
     

Answers
 
 
Old Oct 28, 2008, 04:11 PM   #2  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,977
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Hey Mom,
Your plumber was blowing smoke up your skirt. "S" traps are illegal no matter how close they are to the drain. That's not to say they don't work, we have older homes back in Wisconsin that have been working just fine, thank you, foe decades with no complaints.
You now have four options,
1) Replace the sink with one not as deep.
2) Tear out the sink and cabinet and cut into the wall and stack and lower the sanitary tee and horizontal drain line in the wall.
3) Add a AAV ,( air admittance vent) to the present set up. **or**
4) Simply keep what you have.
Your choice, Good luck, Tom
  Reply With Quote
 
     
 
 
Old Oct 28, 2008, 04:32 PM   #3  
New Member
tm2203 is offline
 
Join Date: Oct 2008
Posts: 3
tm2203 See this member's comment history on his/her Profile page.
Thanks Tom. If I leave the hook-up as is, will I have trouble selling my house? I had new cabinets and granite countertops installed, so at this point they can't be ripped out. How mad should I be at my contractor? Should he have measured the drain height before I ordered my sink? He said he hasn't come across this problem in years and it was always older homes. (Mine is 18 years old). Thanks!
  Reply With Quote
 
     
 
 
Old Oct 28, 2008, 07:06 PM   #4  
Home Repair & Remodeling Expert
ballengerb1 is offline
 
ballengerb1's Avatar
 
Join Date: Dec 2006
Location: Wheaton, Illinois, USA
Posts: 15,392
ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.
Depeends of the quality of the next buyers home inspector. He is likely going to spot the illegal S trap and make the buyer aware of it. The buyer may or may not make an issue of it, too small to be a deal breaker but your plumber is a goof.
  Reply With Quote
 
     
 
 
Old Oct 29, 2008, 05:15 AM   #5  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,977
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Quote:
If I leave the hook-up as is, will I have trouble selling my house? I had new cabinets and granite countertops installed, so at this point they can't be ripped out.
You may be forced to add a AAV for a vent. Depends upon the inspector. I would cross that bridge when I came to it. Good luck, Tom
  Reply With Quote
 
     
 
 
Old Oct 29, 2008, 06:59 PM   #6  
Home Repair & Remodeling Expert
ballengerb1 is offline
 
ballengerb1's Avatar
 
Join Date: Dec 2006
Location: Wheaton, Illinois, USA
Posts: 15,392
ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.ballengerb1 See this member's comment history on his/her Profile page.
tm, not to confuse you but Tom and I may be thinking of two different types of inspectors. A home inspector working for a buy can't make you do anything. He reports flaws to the buyer and then you and the buyer working things out. If someone brought in the local plumbing or building inspector, well lets just say they can make you do a lot of things, period.
  Reply With Quote
 
     
 
 
Old Oct 30, 2008, 08:27 AM   #7  
New Member
tm2203 is offline
 
Join Date: Oct 2008
Posts: 3
tm2203 See this member's comment history on his/her Profile page.
Thanks for all your help. My contractor is coming back to do some trim work on the cabinets. Should I make him add an aav to the present hook-up? I don't want any problems down the line, I'd rather take care of it now- he guarantees his work for one year.
Thanks again!
  Reply With Quote
 
     
 
 
Old Oct 30, 2008, 08:38 AM   #8  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,977
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
I would certainly ask his opinion. He knows the code in your area and can advise you.
You might show him mu options
Quote:
You now have four options,
1) Replace the sink with one not as deep.
2) Tear out the sink and cabinet and cut into the wall and stack and lower the sanitary tee and horizontal drain line in the wall.
3) Add a AAV ,( air admittance vent) to the present set up. **or**
4) Simply keep what you have.
and ask him what he thinks. good luck, Tom
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
How to connect P trap of ceramic toilet to 4" or 3" PVC Line
(4 replies)
70s or 80s "Mouse Trap"-type game
(1 replies)
Sewage pump with strange "trap"
(1 replies)
Broken Concrete trap "Drainage Pipe"
(1 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 03:17 PM.