Question
 
 
#1  
Old Oct 9, 2006, 06:53 PM
red_ryder
New Member
red_ryder is offline
 
Join Date: Oct 2006
Posts: 3
red_ryder See this member's comment history on his/her Profile page.
Replacing cast iron drain pipe????

Put in a dishwasher and was working on the drain when i noticed the 2" cast iron drain pipe wasnt in very good shape. I spliced it with a sawzall ans the put pvc in and tried to use a boot on each end but it still leaks. Then from the cutting another joint in it started to leak. Ive decided its time to replace it with pvc. My dishwasher will feed into it along with my washer and kitchen sink. So i have a couple of questions.
1) Should I replace with 2" pvc or shoudl i go to 3" pvc?
2) my plan is to replace with the cast iron with pvc all the way back to 4 inches or so from the main drain. The joint for the cast iron appears to be leaded in and i dont want to mess with that. So my question is what do i do with the place the pvc meets the cast iron? I thought about a boot but cant find one that fits. I would need a 2' to 21/4 " or something like that. Any help is greatly appreciated.

Reply With Quote
 
     

Answers
 
 
Old Oct 10, 2006, 06:36 AM   #2  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,983
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
"what do i do with the place the pvc meets the cast iron?"
I don't recomend Fernco Neoprene Couplings for anything except a temperary repair. To couple a bald end of a piece of cast iron to a bald end of PVC I recomend using a No-Hub Band.

"1) Should I replace with 2" pvc or shoudl i go to 3" pvc?"
If the piece leaded into the main is 2" then increasing the PVC to 3" would still get choked down to 2"at the joint. However, since disposals and dishwashers were added to the sinks drainage we increased to three inches from two.
Good luck, Tom
  Reply With Quote
 
     
 
 
Old Oct 11, 2006, 05:08 AM   #3  
New Member
red_ryder is offline
 
Join Date: Oct 2006
Posts: 3
red_ryder See this member's comment history on his/her Profile page.
Drain vents Q and hopefully A.

Wanted to start by saying this site is very helpful. Thanks to all who participate. As my thread above states i replaced a 2" cast iron drain pipe with pvc. I then noticed i have no vent at all. So i have an upstairs bathroom and sink. Downstairs i have a dishwasher, washer, 2 sinks, toilet, bathtub. Woould one drain pipe suffice for everything? If not how many should I have? Also could i just splice the upstairs sink drain and take it on outside for a vent? and finally is 3/4 drain pipe big enough for a dishwasher drain ?
  Reply With Quote
 
     
 
 
Old Oct 11, 2006, 07:42 AM   #4  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,983
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
" I then noticed i have no vent at all."
You had no vent on what? The entire house? The downstairs group? Please explain in detail.
"So i have an upstairs bathroom and sink. Downstairs i have a dishwasher, washer, 2 sinks, toilet, bathtub. Woould one drain pipe suffice for everything?"
Would you be asking about the house main? A branch drain? What size are we talking about? I just don't have enough details to answer in depth

" could i just splice the upstairs sink drain and take it on outside for a vent?"
To vent what? The sink? The entire group?

"finally is 3/4 drain pipe big enough for a dishwasher drain ?"

A diswasher discharges through a hose which is connected to a disposal or the sink drainage. What are your plans?
You just haven't furnished enough details. Please explain a little farther. Regards, Tom
  Reply With Quote
 
     
 
 
Old Oct 12, 2006, 03:04 AM   #5  
New Member
red_ryder is offline
 
Join Date: Oct 2006
Posts: 3
red_ryder See this member's comment history on his/her Profile page.
I mean the whole house has no vent. So upstairs i have a toilet that has 5" pvc that runs to the 5" main in the basement. The upstairs sink has 1 1/2" pvc that connects to main in basement close to the connection for the upstairs toilet. Down stairs the tub drain is cast down to the main and the toilet is also cast 5" to main. The sink is 1 1/2" pvc to main. Then there is the dishwasher, kitchen sink and washer which al connect to a 2" pvc pipe that connects to the main at a higher level than the rest. Would splicing the upstairs sink and extending it outside be enough or should i vent the 25' 2 inch pvc as well?

Also the dishwasher is in an island with an electric range. I have ran 1/2" cpvc for the hot water connection. I also have a 3/4 inch barbed connection for the dishwasher drain. Its 3/4" pvc for about 3' and then it hits the 2" pvc drain.
  Reply With Quote
 
     
 
 
Old Oct 12, 2006, 01:21 PM   #6  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 18,983
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Hey Red,

To bring your house up to code every fixture that has a trap must be vented.
If it's been working for all these years then I would leave it be unless you're willing to shell out big bucks.

"the dishwasher is in an island with an electric range. I have ran 1/2" cpvc for the hot water connection. I also have a 3/4 inch barbed connection for the dishwasher drain. Its 3/4" pvc for about 3' and then it hits the 2" pvc drain."
3/4" PVC should handle the discharge from the dish washer. Will the hose be looped to provide a air gap? What 2" drain? Is the drain trapped ? Please explain. regards, Tom
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
Replacing traditional cast iron tub with fiberglass shower unit-HELP
(1 replies)
cast iron soil pipe
(1 replies)
Lead Pipe/cast iron
(4 replies)
cutting cast iron pipe
(7 replies)
Cast iron waste pipe
(2 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 03:36 AM.