I installed a new pressure tank. I filled it, but it did not seem to fill to capacity. There is barely five gallons in there. After flushing the toilet once, the pump kicks in again. Is there anything I need to do to make sure the tank is installed correctly, and that it is working properly?

1 Answer
speedball1's Avatar
speedball1 Posts: 27,651, Reputation: 9541
Senior Plumbing Expert
 
#2

Jul 17, 2008, 04:54 PM


You failed to calibrate your bladder tank. To set the air pressure in a bladder tank, look at the cut-in pressure on your pressure switch. Now drain the line down with the pump off. When there is no more water coming out of the hose bib, set the pressure 2 lbs. Below the cut-in pressure. Check it with a tire gage. If your pressure control is set to come on at 20 PSI and go off at 40 PSI then your gage should read 18 PSI. Hope this helps and thank you for rating my reply.
Helpful

Not your question? Ask your question View similar questions

 
Thread Tools Search this Thread
Search this Thread:

Advanced Search

Add your answer here.

Remove Text Formatting

Undo
Redo
 
Decrease Size
Increase Size
Bold
Italic
Underline
Align Left
Align Center
Align Right
Ordered List
Unordered List
Decrease Indent
Increase Indent
Insert Email Link
Wrap [QUOTE] tags around selected text
Wrap [CODE] tags around selected text
Wrap [HTML] tags around selected text
Wrap [PHP] tags around selected text
Wrap [YOUTUBE] tags around selected text
Notification Type:



Check out some similar questions!

Well pump runs intermitten [ 7 Answers ]

I have a submersible pump 115 ft down. It has a Square D pump pressure control box. It is a 1/2 hp 3 wire pump with a control box near the well. The pressure tank has a bladder. My problem is that the pump stops at times. The pressure gage gets hung. The pressure control box contacts engage...

Heat pump AHU fan runs continuously [ 2 Answers ]

I have a 12 year old Trane Xe1000 heat pump. Recently I noticed that the fan keeps running continuously even when the outside unit turns off. It's as if the tstat fan switch is set to On (it's not) instead of Auto. I tried a few things: 1) In the tstat (weathertron) I disconnected the fan...

Heat Pump runs, blower does not [ 3 Answers ]

My Furnace/Heat Pump seems to be working incorrectly. There are times when the Heat Pump outside will run continously while the thermostat says "heating" however, the blower doesn't come on inside. The coil coming into my furnace unit gets very hot. I have to turn off the unit completely for about...

Outdoor fan on heat pump runs [ 2 Answers ]

The fan on an outdoor carrier unit won't turn off. Turned off at thermostate, tried everything, had to turn it off at the breaker. I am thinking maybe a relay is stuck. Is this a part I can pick up and replace myself or is it a different problem all together Thanks

Why the Sump Pump runs now? [ 4 Answers ]

When I moved in here 2 years ago the sump pumps (have 2) very rarely came on - I did have backup issues (the sewer & sump pumps are on the same line) The reason was tree roots. Recently we decided to air compress the pipe lines to rid the roots. Now, all of a sudden my sump pump decides to run...


View more Plumbing questions Search