    Psi gauge reads 0, doesn't move when boiler is on
    Our furnace is only 3years old, it was expensive. There is a round psi gauge on the front that is always at 0, I've never seen it move. The gauge looks like it is brand new. Could this be the reason we are burning 100 gallons a week, and keeping the thermostat at 60degrees. HELP, we just had it cleaned and nothing was mentioned (perhaps he didn't run it long enough?)
    What can I do to try and fix it.
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #2

    Dec 15, 2010, 05:11 AM

    Hi SS...

    If you have a forced hot water boiler then it sounds like the boiler isn't filled properly with water.

    Most likely, the automatic boiler fill valve has failed and needs to be replaced or it could even be as simple as someone shutting off the water feed into the boiler.

    Here, a forced hot water boiler should have about 12-15 PSI for a reading at that gauge.

    I would fill the boiler system with water and purge all the air out of the system (zone(s)) and then see what happens.

    Be clear that once the old fill valve is disturbed it will probably fill the boiler no problem, but here, the fill valve may not close back down and could cause the boiler to overfill and that could cause the boiler to flood the floor.

    If you are unsure of all I posted on this contact a qualified heat technician/plumber to investigate this for you. I would not call the service technician that cleaned the boiler as they really should have mentioned/noticed this, OK?

    Mark

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Pump will not kick on till gauge reads 0. [ 12 Answers ]

The pump will cut out at 65. I have instaled a brand new preset switch 20/40. Turn on a faucet and the pressure gauge falls to 0. wait a few minutes and the pump kicks on. The air tank is holding pressure.

How do I set my psi on my boiler [ 1 Answers ]

My boiler heats up to 180 but I have no psi according to the gauge

98CIVIC temp gauge reads HOT! [ 1 Answers ]

98 civic recently replaced hoses + thermostat + radiator. The gauge reads hot(about 3/4) when I drive local streets(35-45mph) for about 20 min. When I drive on the free way it goes to about 3/4 very quickly Few days ago I drove on the freeway for a few miles and then when I got off and...

Pressure Transducer not working? I read 80 psi with Gauge - Replace or not? [ 1 Answers ]

OK, So I'm in the process of adding a sprinkler system to the back yard - and I checked the pressure at the hose bibs w/ a pressure gauge - 80 psi. Well, where the water enters the house (in the basement) there is a pressure reducer "set at 50 psi." I'm under the impression that the thing is...

Oil pressure gauge reads zero. [ 1 Answers ]

Hi I have a 1995 jeep wrangler that I just purchased. The oil pressure gauge reads 80 pounds all the time I opened the hood and noticed the eletrical plug was off the oil pressure sending unit. I reinstalled connector and now oil pressure reads zero at idle or 3000 rpm. Do you think sending unit...


View more questions Search