    Proper Vent Size & Wet Venting
    Hello,

    I have an old house (100-years) and have a couple of questions about venting. Here's the details of each floor:

    Basement - washer & utility sink, / shower, sink, & toilet
    1st Floor - kitchen sink, garbage disposal, & dishwasher / sink & toilet
    2nd Floor - tub, sink, & toilet

    My main stack is 4-inch cast iron and appears to be in good/very good condition. Currently, I have a 1 1/2-inch PVC vent (I believe this to be a stacked vent) that runs from the basement to the second floor, where it becomes 2-inch cast iron, then runs to the attic where it ties into the main 4-inch stack that vents through the roof. I'm uncertain if it makes any difference, but each toilet on each floor is located within a few feet (approximately 3-6-feet) of the main stack. And, the 2nd floor bathroom sink vent ties into the system in the attic vs. on the second floor.

    I currently have access to the vent pipe/stack on all three levels. My questions are:

    #1 - Should I have a 2-inch vent vs. the current 1 1/2-inch?

    #2 - Should I vent my basement bathroom group through an un-used 1 1/2-inch cast iron vent that exits the house on the basement stair landing, runs vertical along the brick exterior and vents above the roof/gutter?

    #3 - Can I plumb my 1st floor bathroom sink drain into the current vent? In other words (if I have the language correct), can I wet vent my basement washer and utility sink?


    Thanks,

    -Chad
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Apr 20, 2007, 03:56 PM
    1 - Should I have a 2-inch vent vs. the current 1 1/2-inch?
    Although 1 /2" vents are acceptable in some areas we vent all out new homes with a 3" main vent and 2" for the others.

    #2 - Should I vent my basement bathroom group through an un-used 1 1/2-inch cast iron vent that exits the house on the basement stair landing, runs vertical along the brick exterior and vents above the roof/gutter?

    If it's already there I can see no reason not to use it.

    #3 - Can I plumb my 1st floor bathroom sink drain into the current vent? In other words (if I have the language correct), can I wet vent my basement washer and utility sink?

    What current vent? You have a full bathroom group that you're attempting to wet vent? You haven't given me enough details to give you a answer. Regards, Tom
    muchtodiy's Avatar
    muchtodiy Posts: 4, Reputation: 1
    New Member
     
    #3

    Apr 20, 2007, 06:15 PM
    Tom,

    Thanks for your response. I posted a similar question today. I doubt if I could fit in a 3-inch main vent without doing major demolition and repair work. I'm trying to improve my DWV system, and in doing so would like to meet today's standards if possible.

    #1 - Is a 2-inch main vent adequate for:

    Washer / utility sink - basement
    Kitchen sink with garbage disposal and dishwasher - 1st floor
    Bathroom sink - 1st floor (toilet connects directly to main 4-inch cast iron stack)
    Bathroom group (tub, toilet, sink) - 2nd floor

    The tub and toilet on the second floor connect to this vent on the second floor and the sink on the second floor makes it's connection in the attic, where the vent system connects into the 4-inch cast iron that exits through the roof. Is this vent system called a stacked vent? And, is this venting method acceptable? What else would you recommend?

    #2 - I'll plan on using this un-used 1.5-inch galvanized vent for my basement bathroom group (sink, shower, toilet).

    #3 - I apologize for the poorly written question. I'll plan on connecting my 1st floor bathroom sink drain to the 2-inch kitchen sink drain located in the basement. This method will prevent any wet venting.

    Thanks again,

    -Chad

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Proper venting & using a "Sure-Vent" [ 2 Answers ]

I've attached a PDF showing the layout I'm working with. The items in red are what I would like to add (for a new bar sink). From what I've read online and with checking with local plumbers and since I'm more than 3-1/2' from the main 2" drain line (and I'm using 1 1/2" pipe), I have to vent the...

Compatibilities between awg wiring, breaker amp size, outlet amp size [ 4 Answers ]

Hi. Is there a resource out there, prefereably on the web, that outlines the compatibilities between awg wiring, the breaker amp size, outlet amp size, how many recepticles/outlets can be on x amp outlet, etc? For example, it would be nice to see something that shows: you can use a 20 amp...

Proper venting [ 1 Answers ]

Can a new bathroom, toilet, sink, and shower be vented through an existing 1 1/2" vent? The bathroom will be in the basement, and the vent is part of kitchen on the first floor. Would a 2 1/2" better, or can I use what I have if I tie into the vent above the kitchen sink ? Thank you... Rick

Wet Vent Lav with Shower Vent [ 1 Answers ]

You mention many times that you can wet vent your shower by attaching it to your vented lav drain. Are there any problems doing it the other way around, venting your lav by attaching it to your vented shower drain?

Proper venting [ 3 Answers ]

Hello Experts, My son and I are doing the new DWV system for our house. I have a lot of experience in doing plumbing so I'm not a novice, but I do need to make sure I am doing the venting properly (I know the vent is just as important as the drain lines) as I haven't done anything quite this...


View more questions Search