Old Jul 13, 2008, 03:00 PM
Emfuser
New Member
Emfuser is offline
 
Join Date: Jul 2008
Posts: 9
Emfuser See this member's comment history on his/her Profile page.
Proper fitting to sweat onto copper for tub spout

In my continuing adventures in plumbing, I find myself replacing a tub spout/diverter thanks to a $0.50 piece of plastic that broke while I was re-installing the spout. This was the inside plastic pipe for the spout itself.

So I bought a new universal diverter spout, but noticed when I got home that the piece sweated on to the copper pipe was particular to just that spout, and was not just the easy end of 1/2" copper pipe (it is 1/2" ID pipe, btw).

Ok, so I undid the solder joint, took off that custom piece, and now I have bare pipe sticking out of the wall. I'm not sure if I should be looking for a fitting or some other option to make some threads available to me. What is the proper way for me to proceed here so that I may cleanly attach my universal spout/diverter?

Thanks

Reply With Quote
 
     

Answers
 
 
Old Jul 13, 2008, 03:06 PM   #2  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 14,873
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Quote:
Originally Posted by Emfuser
In my continuing adventures in plumbing, I find myself replacing a tub spout/diverter thanks to a $0.50 piece of plastic that broke while I was re-installing the spout. This was the inside plastic pipe for the spout itself.

So I bought a new universal diverter spout, but noticed when I got home that the piece sweated on to the copper pipe was particular to just that spout, and was not just the easy end of 1/2" or 3/4" copper pipe.

Ok, so I undid the solder joint, took off that custom piece, and now I have bare pipe sticking out of the wall. I'm not sure if I should be looking for a fitting or some other option to make some threads available to me. What is the proper way for me to proceed here so that I may cleanly attach my universal spout/diverter?

Thanks
I would clean the end up and use a slip on tub spout,(see image) but if you have a universal spout then it should just slip on and tighten down. Make sure that the end of the copper has no burrs or rough spots. good luck, tom

Comments on this post
Emfuser agrees: He's right, I had missed the slip on hardware.
  Reply With Quote
 
     
 
 
Old Jul 13, 2008, 03:11 PM   #3  
New Member
Emfuser is offline
 
Join Date: Jul 2008
Posts: 9
Emfuser See this member's comment history on his/her Profile page.
You're right, I had not paid close enough attention, and missed the slip-on hardware. It looks like all I have to do is cut down the length of pipe jutting out from the wall to the length designated on the instructions.

Thanks
  Reply With Quote
 
     
 
 
Old Jul 13, 2008, 03:16 PM   #4  
Senior Plumbing Expert
speedball1 is offline
 
speedball1's Avatar
 
Join Date: Jan 2003
Location: Sarasota, Fl.
Posts: 14,873
speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.speedball1 See this member's comment history on his/her Profile page.
Pay to call speedball1 for advice ($.95/min)
Call speedball1 via Skype™
Don't forget to burr the end of the copper pipe. If you don't the "O" ring will peel back and out of position and you will have a leak out the rear. Cheers, Tom
  Reply With Quote
 
     
 
 
Old Jul 13, 2008, 05:39 PM   #5  
New Member
Emfuser is offline
 
Join Date: Jul 2008
Posts: 9
Emfuser See this member's comment history on his/her Profile page.
Well, I could never get the thing to not leak since the pipe was twisted when I tried to originally remove that first adapter. Having spent an entire Sunday over a broken little piece of plastic, I'm going to suck up my total aversion to destructive home maintenance and call a plumber.
  Reply With Quote
 
     

Bookmarks


Thread Tools
Display Modes

 
Similar Sponsors

Similar Threads
Question Asker Forum Answers Last Post
compression copper fitting to plastic pipe emilyryanemily Plumbing 3 Feb 4, 2008 06:31 AM
if i solder a small copper fitting will the heat melt the existing joints? floofybunny Plumbing 2 Jan 5, 2008 07:18 PM
Copper Pipe Compression Fitting monkeyfarmer Plumbing 7 Sep 29, 2007 04:05 PM
Connecting PVC to Threaded Copper fitting Spierce Plumbing 2 Nov 26, 2006 06:36 AM
Tips on copper compression fitting? harleyds Plumbing 7 Jan 17, 2005 04:32 PM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 03:32 PM.